FUNCTION TEST SEQUENCE
1.
Non-Digital Readout Display Models:
Position the cycle selector knob to the 12 O’clock position.
Digital Readout Display Models:
Position the cycle selector knob to the
Normal
cycle option.
2. Press and hold the
Select
and
Pause Cancel
buttons simultaneously for six seconds.
3. Immediately after, press and hold the
START
and
Pause Cancel
buttons simultaneously for 4 seconds.
The control will enter test mode, the buzzer will sound 3 times and all LED’S will rapidly flash.
After entering the test mode, the program knob can now be rotated to select the following tests:
Rotate the program knob clockwise from the start position:
1 turn:
Drive motor runs; heat source is on.
Drying
LED is lit. “H” and the control thermistor reading will toggle back
and forth in the display.**
2 turns:
Drive motor runs; heat source is off.
Cool Down
LED is lit and “AF” (Air Fluff) is displayed.
3 turns:
Drive motor runs; heat source is off.
Drying
and
Cool Down
LED’s are lit and numbers appear in the display
showing moisture sensor readings. Opening the door (press in on door switch plunger) and placing a finger
on the both moisture sense bars at the same time will make the numbers decrease. In controls that do not
have a digit display, the
MORE DRY
LED should be ON. Opening the door (press in on door switch plunger)
and placing a finger on the both moisture sense bars at the same time will make the
DAMP
LED come on.
4 turns:
Drive motor runs; heat source is off.
Key test:
a. When the
TEMP
button is pressed, all the
TEMP
LED’s should light. If the Temp selector is the
rotary knob, and the knob is rotated, there should be a key beep with each setting.
b. When the
DRYNESS
button is pressed, all the dryness level LED’s should light.
c. When the
OPTION
or
Select
button is pressed, all the Option LED’s should light.
d. When the
START button
is pressed, all the cycle status LED’s should light.
e. When the
Pause Cancel
button is pressed, all the Cycle status LED’s should light.
5 turns:
Drive motor runs; heat source is off.
Cool Down
LED is lit. Control thermistor reading is displayed.**
6 turns:
Drive motor runs; heat source is on.
Drying
LED is lit. Control thermistor reading is displayed.**
**For models that do not have a digital display, the dryness LED’S could be used to determine the control thermistor
temperature reading. The number of flashes of the bottom three LED’S will determine the value of the temperature as
follows.
EXAMPLE:
Normal
flashes 1 time (Normal = HUNDRED’S)
Less Dry
flashes 2 times (Less Dry = TEN’S)
Damp
flashes 6 times (Damp = ONE’S)
Temperature = 126°
To
EXIT the
test mode, press and hold the
SELECT
and
Pause Cancel
buttons simultaneously for six seconds or