F
AULT
RECTIFICATION
© frifri Aro SA
7 - 2
OM - 1.0 - 25.10.2004
7.2
Safety thermostat
The deep fryer is equipped with a safety thermostat according to the current regulations.
The safety thermostat triggers at a temperature of 213 °C.
The safety thermostat switches off the deep fryer in the following situations:
Manual restarting of the deep fryer after an emergency cut-out by the safety thermostat:
CAUTION
•
The control thermostat is defective.
•
Part of the cable connection to the control thermostats is defective or has come loose.
•
Part of the cable connection is not connected or falsely connected to the control thermostats.
•
A power failure (mains) has occurred.
•
The frying oil temperature is too high.
•
The heating elements are heating “dry”, i.e. no frying liquid is present.
•
Too little frying liquid is present.
ADVICE
•
Clarify reason for the triggering of the safety thermostat.
•
Actuate "On/Off" membrane switch.
•
Actuate "Safety reset" membrane switch.