Friedrich ZoneAire Compact P08S Owner'S Manual Download Page 8

MAINTENANCE AND CLEANING 

8. SLEEP CONTROL FUNCTION

1. While in cooling mode, press the SLEEP key to set the temperature. It increases 2°F after an

hour and at most increases  4°F after 2 hours.

2. While in heating mode, press the SLEEP key to set the temperature. It decreases 2°F after

hour and at most decreases 4°F after 2 hours.

3. Press the SLEEP key again to cancel the setting.

9. ALARM

When the water tank is full,"E4" will be displayed on the display panel. To resume operation,
please remove the rubber cap of the drain hose to drain out the water firstly. The E4 warning
will disappear after draining, and then you can restart the unit by pressing the POWER key.

DISPLAY FUNCTIONS

 

In “Sleep” mode, your unit will automatically go into low fan speed allowing the temperature 

to slowly drift up (in cooling) or down (in heating).  See below:   

Summary of Contents for ZoneAire Compact P08S

Page 1: ...ety Guidelines 2 Introduction 3 Unpacking Instructions Contents 4 Parts 5 Display Functions 6 Remote Control Functions 9 Drain Pipe 12 Maintenance Cleaning 13 Installation 14 Troubleshooting 16 P08S P...

Page 2: ...minutes before restarting this is to prevent the compressor from being damaged This unit is for indoor cooling heating and dehumidifying When turning on the unit the fan will operate but the compresso...

Page 3: ...Offers cooling dehumidification bonus heat for year round conditioning and comfort Innovative design One side offers cooling simply turn the unit around and apply the exclusive heat clip for bonus hea...

Page 4: ...se 4 Grip the carry handles located on either sides of the unit and carefully lift until it slides out of the foam base 5 Lift and lean the unit slightly to take out exhaust hose from unit s bottom as...

Page 5: ...PARTS 1 Control panel 2 Remote control receiver 3 Hot air outlet 4 Evaporator s filter 5 Cool air inlet 6 Air outlet s joint part 7 Cool air outlet 8 Condenser s filter 9 Hot air inlet 10 Drain hole 5...

Page 6: ...ion This key lowers the preset temperature by 1 F each time it is pressed and the minimum limit is 63 F During heating function This key lowers the preset temperature by 1 F each time it is pressed an...

Page 7: ...it automatically after the set time is over 1 Press the TIMER key at stand by status to set the time you desired 2 Once the set hour has come to an end the unit will turn on automatically 3 Press the...

Page 8: ...ter 2 hours 3 Press the SLEEP key again to cancel the setting 9 ALARM When the water tank is full E4 will be displayed on the display panel To resume operation please remove the rubber cap of the drai...

Page 9: ...9 REMOTE CONTROL FUNCTIONS Instruction for the operating keys When a remote control signal is transmitted a transmission icon on the display flashes once indicating the signal has been transmitted...

Page 10: ...the keys are pressed without release 5 Power key When this key is pressed the memorized modes and other information about temperature speed direction of airflow sleep etc in the remote control will be...

Page 11: ...will turn on TIMER OFF The timer off is used to turn off the unit automatically after the set time is over 1 Press the TIMER key at stand by status to set the time desired 2 Once the setting hour has...

Page 12: ...ain pipe should be installed in order to improve heating 3 When operating the dehumidifying function the rubber cap on drain hose should be pulled out and proper drain hose should be installed Please...

Page 13: ...ensuring all dust is removed CONDENSER EVAPORATOR Use a brush attachment with a vacuum cleaner CASING Wipe with a damp cloth and polish with a soft cloth To remove the air filter please follow the ar...

Page 14: ...cut off device Please ensure the unit is not placed against objects which will obstruct air intake e g furniture or curtains as this will affect its performance dramatically Do not overextend the exh...

Page 15: ...shown in Fig 01 2 As shown in Fig 02 slide the heat clip connector onto the cooling outlet side of the unit 3 As shown in Fig 03 attach the exhaust hose directly onto the onto heat clip connector 4 R...

Page 16: ...Amps 9A 11A Moisture Removed 63 4 Pints Day 84 5 Pints Day Refrigerant R410A 15 9 ozs 450g R410A Dimensions 11 1 3 W 288mm x 16 6 7 D 428mm x 25 1 5 H 640mm CE N 842 2006 R410A is a kind of fluorinat...