IMPORTANT 

 

Do not install and use your portable air conditioner unit before carefully reading this instruction guide.  

 

Please retain this manual brochure for product warranty and future reference   

IMPORTANT SAFETY GUIDELINES 

CAUTION

 

Operate this unit in an ambient of 89

°

F or less.  

 

The heating function of the unit should  be 

operated in an indoor ambient temperature    

between  44

°

F  and 73

°

F. 

 

Clean air filter periodically to enjoy the most 

efficient cooling. 

 

When the unit is shut off, please wait at least 3.5 

minutes before restarting; this is to prevent  the 

compressor from being damaged.  

 

This unit is for indoor cooling, heating and 

dehumidifying. 

 

When turning on the unit, the fan will operate but 

the compressor will start up after the cooling 

alarm flashes for three minutes. 

 

In heating function, the heating alarm will flash for 

3.5 minutes before the compressor and fan start 

up.                       

 

If you have fuses , they should be of the time delay 

type. Before you install or relocate this unit, be sure 

that the amperage rating of the circuit breaker or 

time delay fuse does not exceed the amp rating 

listed in Table 1. 

Table 1. 

  

  

  

MODEL 

CIRCUIT 

RATING OR 

TIME DELAY 

FUSE 

REQUIRED 

WALL 

RECEPTACLE 

AMP 

VOLT 

NEMA 

NO. 

  

  

P08S,P10S 

  

15 

  

125 

  

5-15P 

  

Summary of Contents for ZoneAire Compact P08S

Page 1: ...ety Guidelines 2 Introduction 3 Unpacking Instructions Contents 4 Parts 5 Display Functions 6 Remote Control Functions 9 Drain Pipe 12 Maintenance Cleaning 13 Installation 14 Troubleshooting 16 P08S P...

Page 2: ...minutes before restarting this is to prevent the compressor from being damaged This unit is for indoor cooling heating and dehumidifying When turning on the unit the fan will operate but the compresso...

Page 3: ...Offers cooling dehumidification bonus heat for year round conditioning and comfort Innovative design One side offers cooling simply turn the unit around and apply the exclusive heat clip for bonus hea...

Page 4: ...se 4 Grip the carry handles located on either sides of the unit and carefully lift until it slides out of the foam base 5 Lift and lean the unit slightly to take out exhaust hose from unit s bottom as...

Page 5: ...PARTS 1 Control panel 2 Remote control receiver 3 Hot air outlet 4 Evaporator s filter 5 Cool air inlet 6 Air outlet s joint part 7 Cool air outlet 8 Condenser s filter 9 Hot air inlet 10 Drain hole 5...

Page 6: ...ion This key lowers the preset temperature by 1 F each time it is pressed and the minimum limit is 63 F During heating function This key lowers the preset temperature by 1 F each time it is pressed an...

Page 7: ...it automatically after the set time is over 1 Press the TIMER key at stand by status to set the time you desired 2 Once the set hour has come to an end the unit will turn on automatically 3 Press the...

Page 8: ...ter 2 hours 3 Press the SLEEP key again to cancel the setting 9 ALARM When the water tank is full E4 will be displayed on the display panel To resume operation please remove the rubber cap of the drai...

Page 9: ...9 REMOTE CONTROL FUNCTIONS Instruction for the operating keys When a remote control signal is transmitted a transmission icon on the display flashes once indicating the signal has been transmitted...

Page 10: ...the keys are pressed without release 5 Power key When this key is pressed the memorized modes and other information about temperature speed direction of airflow sleep etc in the remote control will be...

Page 11: ...will turn on TIMER OFF The timer off is used to turn off the unit automatically after the set time is over 1 Press the TIMER key at stand by status to set the time desired 2 Once the setting hour has...

Page 12: ...ain pipe should be installed in order to improve heating 3 When operating the dehumidifying function the rubber cap on drain hose should be pulled out and proper drain hose should be installed Please...

Page 13: ...ensuring all dust is removed CONDENSER EVAPORATOR Use a brush attachment with a vacuum cleaner CASING Wipe with a damp cloth and polish with a soft cloth To remove the air filter please follow the ar...

Page 14: ...cut off device Please ensure the unit is not placed against objects which will obstruct air intake e g furniture or curtains as this will affect its performance dramatically Do not overextend the exh...

Page 15: ...shown in Fig 01 2 As shown in Fig 02 slide the heat clip connector onto the cooling outlet side of the unit 3 As shown in Fig 03 attach the exhaust hose directly onto the onto heat clip connector 4 R...

Page 16: ...Amps 9A 11A Moisture Removed 63 4 Pints Day 84 5 Pints Day Refrigerant R410A 15 9 ozs 450g R410A Dimensions 11 1 3 W 288mm x 16 6 7 D 428mm x 25 1 5 H 640mm CE N 842 2006 R410A is a kind of fluorinat...

Page 17: ......

Reviews: