background image

CP05

* Feature not available on CP05. ** CP05 has a 

fi

 xed chassis and is for window installation only.

COOL

COOL & HEAT  

COOL

WINDOW AIR CONDITIONERS

CP05

COOL

FITS WINDOWS FROM 

20 

1

/

8

TO

 36" WIDE

Chill

5450 Btu

10.7 EER

Comfort & Convenience

• 24-hour timer 

• Auto air sweep swing louvers* 

provide more even air distribution

• 3 cooling speeds, plus 3 fan-only 

settings; 2 cooling speeds, 2 heating 
speeds, plus fan-only setting on 
Chill+

• Ultraquiet operation

• 4-way air 

fl

 ow control 

• Auto-restart saves settings if power 

is interrupted

Energy Management & 

Compliance

• ENERGY STAR

®

 quali

fi

 ed models

• Money Saver

®

 setting saves money 

by operating the fan only when 
cooling 

Health & IAQ

• Washable, antimicrobial air 

fi

 lter 

• Stale air exhaust

Installation Features

• Slideout chassis*

• Install in window or thru-wall**

• Standard installation hardware

• Expandable side curtains 

• Power cord can run either left or 

right out of the side of the unit 
front*

 

Safety & Security 

Features

• EntryGard

 anti-intrusion protection

Select MODE, FAN SPEED, 
adjust TEMPERATURE and set 
the TIMER.

Chill

6000-23500 Btu

Up to 10.8 EER

Chill

+

Electric  eat

COO ING
8000-23500 Btu

Up to 9.8 EER

E ECTRIC  EAT
3850-12000 Btu

FITS WINDOWS FROM 

20 

1

/

8

TO

 42" WIDE

13

Commercial_Room_Air_Conditioners_Brochure_2013 (6-13).indd   13

6/6/2013   1:51:43 PM

Summary of Contents for WINDOW AIR CONDITIONER

Page 1: ...COMMERCIAL GRADE AND RESIDENTIAL GRADE MODELS THE EXPERTS IN ROOM AIR CONDITIONING ROOM AIR CONDITIONERS www friedrich com ...

Page 2: ... computer with FriedrichLink accessory required p p p p Y Y Auto restart w setting retention Y Y Y Y Auto temp fan speed adjustment Y Y Auto changeover All except EQ08 Air flow directions 8 8 4 4 Auto swing louvers All except CP05 Y Optional color fronts Y Y SOUND REDUCTION TECHNOLOGY Steel inner wall and extra dense insulation Y Y Vibration isolating design and components Y Y Superior airflow des...

Page 3: ...lazed windows actually sandwich low conductance gas between two panes of glass While Friedrich air conditioners may be used with this type of window care should be taken not to break the seal between the two panes of glass during installation Depending on the style of window in the application you may want to consider the cooling solutions in the adjacent chart Professional installers may be able ...

Page 4: ...rich s commitment to quality When designing Kühl our engineers challenged convention to develop the very best window air conditioner on the market Kühl incorporates high end materials like heavy gauge galvanized steel rifled copper tubing and high tech aluminum fins Kühl also uses the most durable components to extend the life of your air conditioner including fully enclosed fan motors that seal o...

Page 5: ...ow systems are tested for powerful and precise air distribution which means faster cooling when you need it most Kühl Quiet Kühl has been engineered for quiet operation Materials have been chosen because of their sound absorption properties and every moving part has been braced and insulated For example extra thick rubber grommets absorb vibration and reduce noise inside while steel inner walls an...

Page 6: ...ems are tested for powerful and precise air distribution using state of the art Computational Fluid Dynamics CFD Sound levels are measured and optimized in our Friedrich sound lab to ensure ultraquiet performance Premium air filters are tested for adsorption capacities and efficiencies The unit s control software is tested for constant and reliable operation Packaging exceeds ISTA International Sa...

Page 7: ...ss the campus Until Friedrich introduced Kühl facilities management had to depend on personnel to remember to turn units off and maintain appropriate operating conditions However Kühl s controls and scheduler now allow facilities operations to control all of their Friedrich units centrally using a hard card system and a daisy chain NYSERDA estimates that Pratt can save 25 on energy consumption And...

Page 8: ...for more details With Kühl you can choose from simple ON OFF operation of a single unit to advanced programming and scheduling Kühl is the first room air conditioner that can tie into a power company s smart grid A grid is a network that brings electricity from power stations to consumers New technologies allow power companies to adjust electrical loads of residential users based on their specific...

Page 9: ... Electric Heat COOLING 7600 Btu Up to 10 5 EER ELECTRIC HEAT 4000 Btu Kühl 7900 36000 Btu Up to 11 2 EER Kühl Electric Heat COOLING 7600 36000 Btu Up to 10 9 EER ELECTRIC HEAT 4000 17300 Btu Kühl Heat Pump COOLING 9500 23500 Btu Up to 10 5 EER HEATING 8000 23500 Btu Full LCD display shows MODE FAN SPEED SET TEMPERATURE and SCHEDULE Adjust TEMPERATURE and FAN SPEEDS set AUTO MODE and turn the SCHED...

Page 10: ...eeve dimensions for 0 years for easy replacement Slideout chassis for more permanent installation and easier access for maintenance Installs in a window or in wall Heavy duty installation hardware lasts longer and provides a superior barrier from the outside elements optional ac cessory on K hl models Rugged hardboard side panels or heavy duty side curt ains on S and E models for a more permanent ...

Page 11: ...d front cover kits available DRAIN KIT Drain tube field installed to the bottom on the base pan Model Kit No SQ and EQ KWCFQ SS ES and YS KWCFS SM EM and YM KWCFM SL EL and YL KWCFL EQ08N11 window kit KWIKQ does not include window brackets C O L O R Deep Red Cobalt Blue Classic Beige Designer White Black Onyx Model Kit No SQ and EQ KWREDQA KWBLUQA KWBGEQA KWWHTQA KWBLKQA SS ES and YS KWREDSA KWBLU...

Page 12: ... design and energy efficient operation including heat cool models Our efficient line of room air conditioners with programmable controls for convenient operation CHILL SLEEK DESIGN And outstanding efficiency Available in a range of capacities with convenience features for carefree cooling and heating 12 ...

Page 13: ...power is interrupted Energy Management Compliance ENERGY STAR qualified models Money Saver setting saves money by operating the fan only when cooling Health IAQ Washable antimicrobial air filter Stale air exhaust Installation Features Slideout chassis Install in window or thru wall Standard installation hardware Expandable side curtains Power cord can run either left or right out of the side of th...

Page 14: ... SM21N30 20500 20000 230 208 9 4 10 3 2181 2128 9 4 9 4 173 6 0 425 M 132 153 SM24N30A 23500 23200 230 208 12 7 13 6 2765 2730 8 5 8 5 221 7 1 430 M 152 167 SL24N30 24000 23800 230 208 11 2 12 0 2553 2532 9 4 9 4 203 7 0 640 L 191 212 SL28N30 27500 27000 230 208 13 5 14 4 2926 2872 9 4 9 4 233 8 5 640 L 193 214 SL36N30 36000 35700 230 208 19 20 5 4235 4200 8 5 8 5 337 12 0 725 L 212 233 Kühl Heat ...

Page 15: ...INCHES Window Width INCHES In wall Installation Finished Hole INCHES Carton Dimensions INCHES Minimum Maximum Height Width Max Depth Height Width Depth Q 14 19 21 3 8 8 5 10 22 42 14 20 8 18 3 4 25 1 2 22 3 4 P1 12 18 15 5 3 10 20 1 8 36 NOT FOR THRU WALL 15 1 4 22 1 4 17 1 2 P6 14 18 3 8 20 7 8 8 1 8 4 11 20 1 8 36 14 1 8 18 7 8 7 17 7 8 22 3 4 22 P7 15 23 5 8 21 8 4 12 25 39 15 23 7 7 8 8 18 3 4...

Page 16: ...Commercial_Room_Air_Conditioners_Brochure_2013 6 13 Printed in USA Friedrich Air Conditioning Co l 10001 Reunion Place Suite 500 l San Antonio TX 78216 l 877 599 5663 l www friedrich com ...