17
CAUTION
Unit Damage Hazard
Failure to follow this caution may result in equipment damage
or improper operation.
Failure to remove shipping tape and screw will prevent fresh
air vent door from opening and may result in damage to vent
door cable.
3.
Carefully remove shipping tape from the front panel and vent door.
See Figure 20
4.
Remove shipping screw from the vent door, if present. See Fig 21.
Figure 21
Shipping Screw Location
Figure 20
ShippingTapeLocation
REMOVE SHIPPING
SCREW IF PRESENT
5.
Remove front panel. See Figure 22.
Figure 22
RemovingFrontPanel
FRP020
FRP022
Pull out at the bottom to release it from the tabs (1). Then lift up (2).
NOTE:
If the unit is mounted flush to the floor, the service cord MUST
be rerouted at the bottom of the front cover on the side closest
to the receptacle. A notch MUST be made in the front cover
side where the cord exits the unit. It is the responsibility of
the installer to create an exit notch.
FRP021
SHIPPING
TAPE
2
1