background image

En-2

FEATURES AND FUNCTIONS

INVERTER

At the start of operation, a large power is used to bring the
room quickly to the desired temperature. Afterward, the air
conditioner automatically switches to a low power setting
for economic and comfortable operation.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY but-
ton on the Remote Control Unit so as to avoid going moldy
and restrain the breed of bacterium.

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched au-
tomatically to maintain the set temperature, and the tem-
perature is kept constant at all times.

MINIMUM HEAT OPERATION

The room temperature can be maintained at 50 °F so as to
prevent the room temperature from falling too far.

PROGRAM TIMER

The program timer allows you to integrate OFF timer and
ON timer operations in a single sequence. The sequence
can involve one transition from OFF timer to ON timer, or
from ON timer to OFF timer, within a twenty-four hour pe-
riod.

SLEEP TIMER

When the SLEEP button is pressed during Heating mode,
the indoor unit’s thermostat setting is gradually lowered
during the period of operation; during cooling mode, the
thermostat setting is gradually raised during the period of
operation. When the set time is reached, the indoor unit au-
tomatically turns off.

WIRELESS REMOTE CONTROL UNIT

The Wireless Remote Control Unit allows convenient con-
trol of indoor unit operation.

SWING OPERATION

The Air Flow Direction Louvers swings automatically up and
down so that the air speeds to every nook and corner of
your room.

REMOVABLE INTAKE GRILLE

The indoor unit’s Intake Grille can be removed for easy clean-
ing and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.

SUPER QUIET OPERATION

When the FAN button is used to select QUIET, the indoor
unit begins super-quiet operation; the indoor unit’s airflow
is reduced to produce quieter operation.

WIRED REMOTE CONTROL UNIT (OPTION)

The optional wired remote control unit (model No.: UTY-RNBLU) can be used.
It requires the Communication Box Kit (Model Name: UTY-XCBXZ1) to connect the wired remote control.
When you use remote control unit, there are following different points as compared with using wireless remote control unit.

[The additional functions for wired ones]
    • Weekly timer
    • Temperature set back timer

[The restricted functions for wired ones]
    • Horizontal Airflow Direction and swing
    • MAINTENANCE

And you can use both wired and wireless remote control unit simultaneously.
(But function is limited.)

[The restricted function for wireless ones]
    • SLEEP
    • TIMER
    • COIL DRY
    • MIN. HEAT

www.sylvane.com  1-800-934-9194

Summary of Contents for MR09Y3H

Page 1: ...English Espa ol Fran ais MODE D EMPLOI MANUAL MW09Y3H MW12Y3H MR09Y3H MR12Y3H CONSERVEZ CE MODE D EMPLOI POUR R F RENCE ULT RIEUR 9332280005 01 www sylvane com 1 800 934 9194...

Page 2: ...placed by the authorized service personal since special purpose tools and specified cord are required Provide occasional ventilation during use Do not direct airflow at fireplaces or heating apparatus...

Page 3: ...set time is reached the indoor unit au tomatically turns off WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of indoor unit operation SWING OPERATION The Air...

Page 4: ...explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current op eration...

Page 5: ...nit a 17 Drain port bottom Fig 6 Remote Control Unit b 1 Signal Transmitter b 2 MODE button b 3 MIN HEAT button b 4 SET TEMP button b 5 COIL DRY button b 6 SLEEP button b 7 TIMER MODE button b 8 FAN b...

Page 6: ...w while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 b 14 Use t...

Page 7: ...About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed P...

Page 8: ...peed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room tempe...

Page 9: ...the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from O...

Page 10: ...Operation Press the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance w...

Page 11: ...m with infants chil dren elderly or sick persons the airflow direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button F...

Page 12: ...m output ECONOMY Operation is approximately 70 of normal air conditioner operation for cooling and heating When ECONOMY operation is performed during the cooling mode dehumidification is improved This...

Page 13: ...lay Fig 7 c 10 will light Then it will disappear after 10 seconds To cancel COIL DRY Operation Press the START STOP button Fig 6 b 9 during COIL DRY Operation The indoor unit COIL DRY Indicator Lamp y...

Page 14: ...nd push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the indoor unit without Intak...

Page 15: ...in con densation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation i...

Page 16: ...ent heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculat...

Page 17: ...ading to water leakage and other damage Do not use this air conditioner for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings If the air cond...

Page 18: ...Friedrich Air Conditioning Co 4200 N Pan Am San Antonio Texas 78218 USA Tel 210 357 4400 Fax 210 357 4490 Visit us at www friedrich com www sylvane com 1 800 934 9194...

Reviews: