background image

En-12

SWING OPERATION

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.

How To Use the Main Unit Controls

Press the MANUAL AUTO button  (Fig. 2 a-2) for three sec-
onds on the main unit control panel.

To stop operation, press the MANUAL AUTO button (Fig. 2 a-2) for three seconds.

When the air conditioner is operated
by the controls on the Main Unit, it will
operate under the same mode as the
AUTO mode selected on the Remote
Control Unit (see page 6).

The fan speed selected will be “AUTO”
and the thermostat setting will be
standard (76 

°F

).

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and
restrain the breed of bacterium.
The COIL DRY operation will operate for 90 minutes after pressing the COIL DRY button and it will stop automatically.

To select COIL DRY Operation

Press the COIL DRY button (Fig. 6 b-5) during operation or when
it stops.

The COIL DRY Display (Fig. 7 c-10) will light. Then, it will disappear after 10 seconds.

To cancel COIL DRY Operation

Press the START/STOP button (Fig. 6 b-9) during COIL DRY
Operation.

The indoor unit COIL DRY Indicator Lamp (yellow) (Fig.1 a-7) will go out. Then, the
operation stops.

About COIL DRY Operation

Press the COIL DRY button again during COIL DRY Operation, COIL DRY Opera-
tion can be reset.

The COIL DRY Operation cannot get rid of the existed mold or bacterium, and it
has no sterilization effect either.

Begin air conditioner operation before performing this procedure.

To select SWING Operation

Press the SWING button (Fig. 6 b-12).

The SWING Display (Fig. 7 c-4) will light.
In this mode, the Air Flow Direction Louvers will swing automatically to direct the
air flow both up and down.

To stop SWING Operation

Press the SWING button (Fig. 6 b-12) once again.

The SWING Display (Fig. 7 c-4) will go out.
Airflow direction will return to the setting before swing was begun.

About Swing Operation

During cooling/Dry mode : Swings between 1 and 4.
During heating mode

: Swings between 4 and 6.

The SWING operation may stop temporarily when the air conditioner’s fan is not
operating, or when operating at very low speeds.

www.sylvane.com  1-800-934-9194

Summary of Contents for MR09Y3H

Page 1: ...English Espa ol Fran ais MODE D EMPLOI MANUAL MW09Y3H MW12Y3H MR09Y3H MR12Y3H CONSERVEZ CE MODE D EMPLOI POUR R F RENCE ULT RIEUR 9332280005 01 www sylvane com 1 800 934 9194...

Page 2: ...placed by the authorized service personal since special purpose tools and specified cord are required Provide occasional ventilation during use Do not direct airflow at fireplaces or heating apparatus...

Page 3: ...set time is reached the indoor unit au tomatically turns off WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of indoor unit operation SWING OPERATION The Air...

Page 4: ...explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current op eration...

Page 5: ...nit a 17 Drain port bottom Fig 6 Remote Control Unit b 1 Signal Transmitter b 2 MODE button b 3 MIN HEAT button b 4 SET TEMP button b 5 COIL DRY button b 6 SLEEP button b 7 TIMER MODE button b 8 FAN b...

Page 6: ...w while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 b 14 Use t...

Page 7: ...About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed P...

Page 8: ...peed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room tempe...

Page 9: ...the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from O...

Page 10: ...Operation Press the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance w...

Page 11: ...m with infants chil dren elderly or sick persons the airflow direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button F...

Page 12: ...m output ECONOMY Operation is approximately 70 of normal air conditioner operation for cooling and heating When ECONOMY operation is performed during the cooling mode dehumidification is improved This...

Page 13: ...lay Fig 7 c 10 will light Then it will disappear after 10 seconds To cancel COIL DRY Operation Press the START STOP button Fig 6 b 9 during COIL DRY Operation The indoor unit COIL DRY Indicator Lamp y...

Page 14: ...nd push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the indoor unit without Intak...

Page 15: ...in con densation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation i...

Page 16: ...ent heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculat...

Page 17: ...ading to water leakage and other damage Do not use this air conditioner for any purposes other than the Cooling Heating Dehumidifying and air circulation of rooms in ordinary dwellings If the air cond...

Page 18: ...Friedrich Air Conditioning Co 4200 N Pan Am San Antonio Texas 78218 USA Tel 210 357 4400 Fax 210 357 4490 Visit us at www friedrich com www sylvane com 1 800 934 9194...