25
ENGL
I
SH
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
A
B
CAUT
I
ON
Capacity is based on standard length and maximum allowable length is on the basis of
reliability. Additional refrigerant must be charged after 7.5m(24.6ft).
!
Oper
ation
r
an
ge
s
Mode
Indoor temperature
Outdoor temperature
Cooling
18°C ~ 32°C (64.4°F ~ 89.6°F) -10°C{-18°C}*~48°C(14°F{-0.4°F}*~118.4°F)
Heating
16°C ~ 30°C (60.8°F ~ 86°F)
-20°C ~ 24°C (-4°F ~ 75.2°F)
The table below indicates the temperature ranges the air conditioner can be Operated within.
{ }* : use wind baffle kit
Capacity
(Btu/h)
Pipe Size
Standard
Length
m(ft)
Max.
Elevation
Ⓑ
m(ft)
Min
Length
Ⓐ
m(ft)
Max.
Length
Ⓐ
m(ft)
Additional Refrig-
erant for longer
than 7.5m(24.6ft)
GAS
LIQUID
mm
inch
mm
inch
g/m
oz/ft
24k, 30k, 36k Ø15.88
5/8
Ø9.52
3/8
7.5(24.6) 30(98.4)
-
50(164)
35
0.38
P
i
p
in
g Le
n
g
t
h
an
d E
l
ev
ation