16
10 – TEMPERATURE RECOVERY TIME
00-60 (25* factory setting) Select the maximum time allowed for a PTAC unit to attain
temperature as defined by Heat and Cool “Recovery Temperature”;
“Temperature Recovery Time” selected here and the actual temperature recovery
ability of the PTAC unit are used to calculate setback temperatures. Calculated setback
temperatures maximize energy savings and at the same time ensure that a comfortable
room temperature (defined as Heat and Cool “Recovery Temperature”) will be restored
within the selected “Temperature Recovery Time”.
Setting the “Temperature Recovery Time” to “00”, disables temperature recovery. When
temperature recovery is disabled, thermostat will use the Minimum and Maximum Setback
Temperatures as setback setpoints.
Custom Energy Savings Settings
11 – RECOVERY TEMPERATURE - HEAT
62-82 (66°F* factory setting) Select the room temperature in °F that a PTAC unit will have to
attain within the selected “Temperature Recovery Time” when there is a need for heating.