background image

Level

STEP 2 – Hang wall mount bracket

Using the paper template as a guide, locate two studs

behind screw hole locations in the template. It is

preferable to mount the hanging plate on studs. If two

studs are not available, utilize anchors appropriate for

the wall type with a combined weight capacity of at least

60 lbs. Standard wood screws and drywall anchors are

provided.
If you are installing the system by drilling a 3” hole

through the wall (Option 1), mark the location of the 3”

hole centerline on the wall as well
Note that the indoor unit is not centered on the bracket. 

There is a center line on the paper template which 

shows where the center of the indoor unit will be after 

installation.

STEP 3 – Drill hole (Option 1) or mount 

SimpleSill™ (Option 2).  

Always follow all local and national codes when in-

stalling equipment.  Obtain the help of trained, skilled 

worker where necessary.

Option 1: Drill hole Through-the-Wall Installation

Drill 3” hole through the exterior wall.

NOTE

:  This should only be done by qualified install

-

ers.  Consult local and national codes before drilling any 

holes. Mark the hole location on the indoor wall using 

the template. (If locating unit above a window or door, 

make sure the hole is above structural header)

Using a stud finder, scan area around desired hole loca

-

tion for pipes, ducts, electrical conductors and struc-

tural elements. Relocate indoor unit mounting location 

as necessary to avoid interference.
Using a 3” hole saw, drill hole through wall from inside 

toward outside. When hole saw cuts through inside wall, 

stop drilling. 

DO NOT drill the entire 3” hole from the 

inside to prevent insulation and exterior wall damage. 

Depending on the type of insulation, it might be neces-

sary to trim excess insulation prior to completing the 

hole. Once insulation is removed, continue drilling from 

inside until center drill bit of the saw just penetrates the 

outside wall. 

TIP: Tape a bag to the wall directly below hole location to 

catch drill debris and dust or use a shop vacuum while 

drilling.

Complete 3” hole from outside of the home

 by locating 

center spiral drill bit penetration.  Using the 3” hole saw 

finish drilling through the wall from the outside of the 

home. 

Now that you have determined where the modules will be placed, it is time to install the Breeze air conditioning system.

Paper template

NOTE:

Attach the wall 

bracket to the wall 

with at least two 

screws capable of 

securing at least 

60 lbs.

3” hole location

NOTE: Wall mount bracket ships mounted to the back of the indoor 

unit with a single Phillips head screw. Remove screw to release the 

bracket for installation. 

Option 1 installation: remove 

small knockout for power 

cord only.

Option 2 installation: remove full 

knockout for power cord and con-

necting line.

3.1

3.2

Summary of Contents for Breeze BR1224W3A

Page 1: ...tions for BR1224W3A 12000 24000 Btu Breeze A revolution in room cooling Friedrich Part No 96091001 Service Questions Contact Friedrich at 800 541 6645 Sales Inquiries Contact Sylvane at 800 934 9194 o...

Page 2: ...module off of the ground 3 The fan should face away from the building 25 ft max 6 ft power cord NOTE Be sure to place your equipment with these limitations in mind 25 ft connecting line 6 ft power cor...

Page 3: ...sold DO NOT PLUG IN INDOOR UNIT until you have completed the entire installation process CAUTION SHOCK HAZARD DO NOT PLUG IN indoor unit until all installation work is completed Connect to a single de...

Page 4: ...red hole loca tion for pipes ducts electrical conductors and struc tural elements Relocate indoor unit mounting location as necessary to avoid interference Using a 3 hole saw drill hole through wall f...

Page 5: ...odule on the wall bracket Hang the module at the top first and rotate it down until the module is level with the wall You may need to make adjustments to the connecting line to get the indoor module t...

Page 6: ...sing enclosed 8 x 3 4 screw located on the top flange of the quick connect cover All Covers must be in place to operate unit SHOCK HAZARD exists without electrical access cover Cover cannot be install...

Page 7: ...at removes the moisture collected from the indoor module The hose must be located in an appropriate location for drainage Because the hose relies on gravity to drain it is important that the hose only...

Page 8: ...rn on the AUTO AIR SWEEP function or to set the desired angle of the airflow Airflow angle is reset each time power is turned off 8 EXTEND When on will be displayed In Cooling and Dry mode this will a...