Friedrich Breeze BR1224W3A Installation Instructions Manual Download Page 2

Before getting started

Identify the locations where you will mount the indoor 

module and place the outdoor module.  Keep in mind, 

there is 25’ of connection line for connecting indoor and 

outdoor pieces, so locate them accordingly.  

You cannot 

add additional length if they are too far apart.

Placing the indoor unit

It is recommended that you install the indoor module on 

an exterior wall within 6 feet of a properly rated outlet 

for the system you are installing. The BR1224W3A plugs 

into a 230V 15A outlet. The system should be plugged 

into a single circuit outlet only. Typically, hanging the 

indoor module above or adjacent to a window will 

provide a great location. NOTE: You should not drill 

through the window header (part of the rough framing) 

located directly above the window opening.

 

Placing the outdoor unit

The outdoor module should be placed on a level surface 

with adequate clearance from items like shrubbery, 

solid fencing or other air conditioning equipment that 

can impede airflow to the module. 

The outdoor module must be at least 12” from the wall 

for proper airflow.  The mounting pad provided with the 

system will raise the module off of the ground 3”. The 

fan should face away from the building.

25 ft. max.

6 ft. 
power 
cord

NOTE:
Be sure to place your 
equipment with these 
limitations in mind.

25 ft. 
connecting 
line

6 ft. power 
cord

DO NOT PLUG IN INDOOR UNIT until you have 

completed the entire installation process.

12

"

 minimum 

clearance

6

"

 mi

nim

um 

cle

ara

nce

6

"

 min.

6

"

 min.

What’s in the carton?

1.  Breeze indoor module with 25 ft. connecting 

line attached

2.  Wall mounting template and bracket for in-

door module

3.  Breeze outdoor module

4.  Outdoor module connection covers

5.  Mounting pad for outdoor module

6.  Remote control

7.  Accessories (see list at right)

Tools you will need:

• 

Phillips screwdriver 

• 

1/2” wrench or crescent wrench

• 

Drill with Phillips bit and 3/16” drill bit

•  Stud finder (recommended)

• 

3” hole saw (through wall installations)

• 

Safety glasses (recommended)

• 

Trim knife

• 

Level

1

.

2.

3.

4.

5.

7.

8.

11.

6.

9.

10.

14.

Accessories

ITEM  DESCRIPTION 

QTY

1. 

CONTROL BOX COVER DOOR 

1

2.  

CONTROL BOX COVER 

1

3.  

QUICK CONNECT COVER 

1

4.  

WIRE TIE 

2

5.  

CONNECTING LINE BENDING GUIDE 

1

6.  

ELECTRICAL CORD RETENTION BRACKET 

1

7.  

WALL OPENING FILL GASKET 

1

8.  

OUTDOOR UNIT ANCHOR SCREW 

4

9.  

OUTDOOR UNIT WASHER FOR ANCHOR SCREW  4

10.  

SCREW #8 X 3/4” TRUSS HEAD 

6

11 

SCREW #6 -19X.375 HEX HEAD 

1

12.  

WALL ANCHOR FOR #8 X 1 1/2” SCREW 

15

13.  

SCREW #8 X 1 1/2” PHILLIPS PAN HEAD 

15

14.  

CONNECTING LINE CLIPS 

5

12.

13.

Summary of Contents for Breeze BR1224W3A

Page 1: ...tions for BR1224W3A 12000 24000 Btu Breeze A revolution in room cooling Friedrich Part No 96091001 Service Questions Contact Friedrich at 800 541 6645 Sales Inquiries Contact Sylvane at 800 934 9194 o...

Page 2: ...module off of the ground 3 The fan should face away from the building 25 ft max 6 ft power cord NOTE Be sure to place your equipment with these limitations in mind 25 ft connecting line 6 ft power cor...

Page 3: ...sold DO NOT PLUG IN INDOOR UNIT until you have completed the entire installation process CAUTION SHOCK HAZARD DO NOT PLUG IN indoor unit until all installation work is completed Connect to a single de...

Page 4: ...red hole loca tion for pipes ducts electrical conductors and struc tural elements Relocate indoor unit mounting location as necessary to avoid interference Using a 3 hole saw drill hole through wall f...

Page 5: ...odule on the wall bracket Hang the module at the top first and rotate it down until the module is level with the wall You may need to make adjustments to the connecting line to get the indoor module t...

Page 6: ...sing enclosed 8 x 3 4 screw located on the top flange of the quick connect cover All Covers must be in place to operate unit SHOCK HAZARD exists without electrical access cover Cover cannot be install...

Page 7: ...at removes the moisture collected from the indoor module The hose must be located in an appropriate location for drainage Because the hose relies on gravity to drain it is important that the hose only...

Page 8: ...rn on the AUTO AIR SWEEP function or to set the desired angle of the airflow Airflow angle is reset each time power is turned off 8 EXTEND When on will be displayed In Cooling and Dry mode this will a...