9
Maintenance
The product may be cleaned with a soft
damp cloth and then wiped dry. Do not
use abrasive, solvent based or aerosol
cleaners as this may damage and/or
discolour the product. Take care not to
accidentally move the detector head.
Do not allow water to enter or attempt to
clean inside the units.
Changing the PIR battery:
Change the PIR battery immediately the
low battery indication is noticed, (i.e. the
red LED behind the detector lens flashes 5
times after each movement detection).
Only fit a new Alkaline PP3 (6LR61) battery.
Disposal & Recycling
At the end of their useful life the
packaging and product should be
disposed of via a suitable Recycling
Centre. Do not dispose of with your
normal household waste.
DO NOT BURN.
Specification
PIR DETECTOR
Battery:
9V PP3 (6LR61) Alkaline battery
Battery life:
Approx 12 months
(based on 20 activations per day and constant 15°C)
PIR detection range:
12m
PIR detection angle:
140°
Time on adjustment:
5 secs - 20 mins
Photocell adjustment:
5 lux to daylight
Protection:
IP54
Operating Frequency:
868MHz
RF range:
up to 200m (in open field conditions)
Operating temperature:
-20°C to +35°C
Declaration
Novar ED&S hereby declares that this
Wirefree PIR Detector is in compliance
with the essential requirements and other
relevant provisions of the Radio and
Telecommunications Terminal Equipment
(R&TTE) directive, 1999/5/EC.