L
N
E
●
Feed the cables through the grommets
as required ensuring the grommet is
correctly fitted in the hole.
●
Push the fixing screws through the
rubber sealing plugs. Fix the unit to the
wall and tighten the screws ensuring that
the rubber seals are correctly seated.
●
Cut the cable to length so that it
comfortably reaches the terminals and
can be neatly fitted in the enclosure
without interfering with the lid when it s
fitted and then carefully trim the insulation
of the cable wires removing about 6mm
from the ends.
●
Connect the power supply cable to
Terminal Block A and the cable from the
lighting load to Terminal Block B as follows:
Cable
Supply
Load
Colour
Terminals A
Terminals B
LIVE
L
L1
Brown
NEUTRAL
N
N
Blue
EARTH
Green/Yellow
Installing the Receiver
●
Undo the four cover screws and remove
the cover.
●
Select the required cable access holes
according to your wiring route and prepare
and fit the cable grommets as necessary.
Ensure that the pierced grommets are
properly positioned in the entry holes and
that blank unpierced grommets are fitted
in the unused entry points.
If the rear access hole is needed, use
firm pressure with your screwdriver to
remove the knock out and then clean up
the edges of the hole with a sharp knife
to ensure a good seal for the grommet.
If the cable to be passed through the
access opening is too large in diameter
to fit, break out the extra material with a
small screwdriver or pliers to create a
larger opening making sure that all sharp
edges are removed.
●
Hold the receiver in the required position,
ensuring that it is on a flat surface, and
ensure that the cables will be able to
enter the chosen entry holes and reach
the terminals.
Mark the position of the fixing holes and
drill two 6mm holes, then insert the wall
plugs (supplied).
Note:
If fixing to non-solid or wood surface
the wall plugs will not be needed and
only a small pilot hole will be required.
4
Fig. 1
Any bare Earth
wire must be
fitted with
Green/Yellow
sleeving
Any bare Earth
wire must be
fitted with
Green/Yellow
sleeving
Terminal Block
A Supply
Connections
Terminal Block
B Supply
Connections
Lamp
Summary of Contents for Spectra Plus L420N BLK
Page 91: ...RUS Spectra Plus PIR Friedland Libra Plus 90 L420N WHI and L420N BLK...
Page 92: ...91 BS7671 230 2 3 6 PIR 2 4 4 2 9V PP3 6LR61...
Page 94: ...6 A B L N E 6 93 A B L L1 N N A B P 1...
Page 95: ...1 5 94 PIR PIR 200 2 5 12 P 2 P 3...
Page 97: ...96 PIR 1 2 5 5 P 6 5 P 7...
Page 98: ...97 P 8 PIR 1 5 20 2 3 4...
Page 99: ...0 5 2 6 10 PP3 1 30 5 PIR Libra Plus 10 3 Spectra Plus 3 98...
Page 100: ...ID Libra Plus Friedland Libra Plus 3 Libra Plus 3 ID 10 5 ID 99...
Page 102: ...101...
Page 103: ...5 PP3 6LR61 Novar ED S Radio and Telecommunications Terminal Equipment R TTE 1999 5 EC 102...