FRIEDLAND MA7 Installation And Operating Instructions Download Page 4

45379PL Ed.1

Friedland, Novar Electrical Devices and Systems

The Arnold Centre, Paycocke Road, Basildon, Essex.  SS14 3EA

www.friedlandsecurity.com

TROUBLE SHOOTING

Remote Control Not Operating

Batteries low, flat, missing or incorrectly fitted.

Infra-Red Transmitter LED obscured.

Remote Control not pointing directly at 
PIR Alarm Unit.

PIR Alarm Unit Not Operating

Batteries low/flat, missing or incorrectly fitted.

House code not programmed.

PIR Causing False Alarms

PIR Badly positioned, (e.g. in direct sunlight, 
draughts, above a radiator etc.).

Magnetic Contact Not Operating

Gap between contact and magnet >12mm 
when door closed.

Arrows on magnet and alarm PIR Alarm 
Unit not in line.

Cable broken or not connected to PIR 
Alarm Unit.

MAINTENANCE

The product may be cleaned with a soft damp
cloth and then wiped dry.  Do not use
abrasive, solvent based or aerosol cleaners as
this may damage and/or discolour the product.

Do not allow water to enter or attempt to clean
inside the unit.

Replacement Batteries:

Remove batteries before storing the Alarm and
Remote Control for extended periods.  Do not
allow batteries to corrode and leak as this may
cause permanent damage to the product.  Do not
mix new and old batteries or different types of
batteries.  Do not fit rechargeable batteries.

Remote Control :

4 x 1.5V A76 (LR44) 
Button Cells

PIR Alarm Unit :

3 x AA (LR6) 
Alkaline batteries

Important:  Take care to insert the batteries
with the correct polarity as shown inside the
battery compartments.

Note: After replacing the batteries in the PIR
Alarm Unit check that it still responds to the
Remote Control.  It may be necessary to
reprogram the system House Code into the
PIR Alarm Unit.

At the end of their useful life the
batteries should be disposed of
via a suitable Recycling Centre.
Do not dispose of with your
normal household waste.  DO NOT BURN.

GUARANTEE 

Novar ED&S undertakes to replace or repair at its discretion goods (excluding non rechargeable batteries)
should they become defective within 2 years solely as a result of faulty materials and workmanship.
Understandably if the product has not been installed, operated or maintained in accordance with the
instructions, has not been used appropriately or if any attempt has been made to rectify, dismantle or alter
the product in any way the guarantee will be invalidated.

The guarantee states Novar ED&S entire liability.  It does not extend to cover consequential loss or
damage or installation costs arising from the defective product.  This guarantee does not in any way affect
the statutory or other rights of a consumer and applies to products installed within the UK and Eire only.

If an item develops a fault within the first year, it should be returned to the point of sale with:

1)   Proof of purchase.      2)   A full description of the fault.      3)   All relevant batteries (disconnected).

In the second year it should be returned direct to Friedland Technical Sales Services Department at the
address shown below.

Friedland is a trademark of Novar ED&S.

HELPLINE

If you have any problems with your 

alarm, please call the Helpline on:

01268 563273

(Lines open 9.00am to 5.00pm, Monday to Friday)

Summary of Contents for MA7

Page 1: ...tion Passive Infra Red PIR detectors are designed to detect movement in an area by detecting changes in infra red radiation levels caused for example when a person animal moves within the devices field of vision The Magnetic Contact Detector is fitted along the opening edge of a door window and is used to detect when the door window is opened The system has 2 operating modes ALARM and CHIME Chime ...

Page 2: ...d 7 Fix Magnetic Contact Switch to fixed part of door window frame beside the Magnet using the adhesive pad supplied Ensure that the gap between the Magnet and Contact Switch is less than 12mm when the door window is closed and the arrows align 8 Run the cable back to the PIR Alarm Unit the cable cannot be extended PIR Alarm Unit 9 Hold the mounting bracket in position on the wall and mark the pos...

Page 3: ...en will activate The entry delay allows time for you to DISARM the alarm before the siren activates Unplugging or cutting the cable to the magnetic contact detector will also trigger the alarm subject to the entry delay period The siren will continue for 60s before stopping Any further triggering of the alarm either by opening the protected door window or movement in front of the PIR will immediat...

Page 4: ...ttery compartments Note After replacing the batteries in the PIR Alarm Unit check that it still responds to the Remote Control It may be necessary to reprogram the system House Code into the PIR Alarm Unit At the end of their useful life the batteries should be disposed of via a suitable Recycling Centre Do not dispose of with your normal household waste DO NOT BURN GUARANTEE Novar ED S undertakes...

Reviews: