10.5. Too much ice on the equipment walls
•
Check that the AD equipment performs automatic defrost.
•
Check that the lid seals are correct.
•
Check if there is a product leaning against the inside walls.
•
Check if the defrost chute resistor is damaged.
•
Check if the local conditions exceed the equipment’s climate classification
(found on the characteristics label).
10.6. High energy consumption
•
Check if the set-point is at maximum.
•
Check if the condenser is blocked.
•
Check if the doors are properly closed.
•
Check if the local conditions exceed the equipment’s climate classification
(found on the characteristics label).
•
Check the equipment’s ventilation channels (correct distance between objects
or if cooling fan motor is operating).
10.7. Condensation in the equipment
•
Check if the set-point is at maximum.
•
Check if the products are over the load limit.
•
Check if the glass is dirty or obstructed with adhesives.
•
Check if the external conditions exceed the limit of the equipment’s normal
operation.
If none of the above scenarios apply, we advise that you contact an authorized dealer.
•
Never attempt to repair the equipment or its electrical components by your own
endeavour. Any repairs made by an unauthorized individual are dangerous to
the user and may result in the warranty’s nullification.
•
In case of gas leak, keep your distance from the equipment, do not try to repair
or locate the leak.
•
In case of gas leaks or fire, do not use water to extinguish the flames, but only
dry-agent extinguishers.
•
In case of accident / failure:
o
Air the place where the equipment is located.
o
Do not cause a spark near the equipment.
o
Cut the power of the equipment.
o
Check the windows for damage before cleaning.
o
Contact technical assistance.
WARNING