background image

Thermowarm TWS

15

GB

Handling of product at end of working life

This product may contain substances 
necessary for functionality of product but 
potentially dangerous for the environment. 
The product should not be disposed 
mixed with general household waste but 
delivered to a designated collection point for 
environmental recycling. Please contact local 
authority for further details of your nearest 
designated collection point.  
 

Safety  

• 

For all installations of electrically heated 
products should a residual current circuit 
breaker 300 mA for fire protection be used.

 

• 

Keep the areas around the air intake 
and exhaust grilles free from possible 
obstructions!

• 

The unit must not be fully or partially 
covered as overheating can result in a fire 
risk! 

• 

This appliance can be used by children 
aged from 8 years and above and persons 
with reduced physical, sensory or 
mental capabilities or lack of experience 
and knowledge if they have been given 
supervision or instruction concerning 
use of the appliance in a safe way and 
understand the hazards involved. Children 
shall not play with the appliance. Cleaning 
and user maintenance shall not be made 
by children without supervision. 

 

• 

Children of less than 3 years should be 
kept away unless continuously supervised. 

• 

Children aged from 3 years and less than 8 
years shall only switch on/off the appliance 
provided that it has been placed or 
installed in its intended normal operating 
position and they have been given 
supervision or instruction concerning 
use of the appliance in a safe way and 
understand the hazards involved. 

• 

Children aged from 3 years and less 
than 8 years shall not plug in, regulate 
and clean the appliance or perform user 
maintenance.  

CAUTION — Some parts of this product can 
become very hot and cause burns. Particular 
attention has to be given where children and 
vulnerable people are present. 

Summary of Contents for Thermowarm TWS Series

Page 1: ...ThermowarmTWS 4 SE 14 GB Original instructions 24 NO 34 DE 44 FR 54 NL 64 FI 74 ES 84 RU 94 PL ...

Page 2: ...ThermowarmTWS 2 TWS Fig 1 Fig 2 Minimum distances min 50 min 100 min 300 min 70 333 453 753 242 362 662 47 123 208 150 Accessories TWSL TWSL12 TWS100 200 TWSL3 TWSC on off Overheat protection reset ...

Page 3: ...0 230V 1 7 TWSE105 500 230V 2 2 TWSE110 1000 230V 3 2 TWSD110 1000 400V 3 2 Type Output W Voltage V Weight kg TWSE205 500 230V 2 2 TWSE210 1000 230V 3 2 TWSD210 1000 400V 3 2 Type Output W Voltage V Weight kg TWSC303 300 230V 1 7 TWSC305 500 230V 2 2 TWSC310 1000 230V 3 2 TWS Overheat protection C SENSOR RESISTOR L N ON OFF ...

Page 4: ...of the right hand plastic side See wiring diagrams Replacement of cable If the cable is damaged the unit must be sent to Frico for replacement Contact Frico Technical Support Start up When the unit is used for the first time or after a long period of disuse smoke or odour may result from dust or dirt that has collected on the element This is completely normal and disappears after a short time Serv...

Page 5: ...with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unles...

Page 6: ...y At the first start up or after a longer power failure the time needs to be set If a week program is not to be used and the time does not need to be set this can be overridden by pressing the OK button repeatedly until the home screen appears When starting up for the first time or after an extended power failure a test sequence is run first after which all the symbols are displayed on the screen ...

Page 7: ... current week program Black timing marks comfort mode Open window mode on Programme number 12H AM PM or 24H Current room temperature actual value Settings menu Function in AUTO mode override Flashing ITCS function Heat on Current day Symbols for programme selection 1 2 Display lock on 1 2 ...

Page 8: ... date Select Confirm OK Set the following hour 24 h minute weekday Mon 1 Sun 7 day month year Increase decrease using Confirm each step with OK Automatic mode weekly programme See the Settings menu Press Quick command Quick commands Switch between current room display tempera ture actual value and set point value Switch between display time current room tem perature actual value and set point valu...

Page 9: ... 15 minutes 44 days minute h hour d day While the timer is running its symbol flashes and the display alternately shows the remaining time and the set temperature When time is up the unit returns to previous settings User menu Set the desired time Select Confirm OK Confirm OK Set the desired room temperature Confirm OK ...

Page 10: ...an be deactivated see Settings menu Preset programs Mon Fri Sat Sun Residence Program Description Comfort mode Residence late Residence short Shop late Shop Weekend Residence day only Office Office late Mon Sun Mon Fri Mon Fri Mon Fri Sat Sun Fri Sat Sun Mon Fri Sat Sun Mon Fri Sat Sun Mon Fri Sat Sun Read more on the following pages P1 05 30 08 17 22 07 23 P2 06 30 10 19 23 30 07 30 23 30 P3 06 0...

Page 11: ...e made in the same way as for Monday 1 Once all 7 days are complete Confirm with ok to start the program OK Advance the time in 30 minute intervals It is now possible to copy the previous day COPY Temporarily override the weekly programme It is easy to temporarily disregard the set point temperature according to the weekly programme Select the desired temporary set point temperature Confirm OK The...

Page 12: ... displayed the offset value is zero and sensor calibration has not been performed When calibration of the sensor is to be performed the set point value must have been constant for at least 24 hours 1 Measure the temperature in the room using a thermometer at the same height above the floor as the convector 2 Enter this value in Settings menu Calibration of temperature sensor 5 with Confirm with OK...

Page 13: ...e format For week program Daylight saving sum mer time and winter time Switch betweenYES and no using Confirm with OK Switch between C and F using Confirm with OK Switch between 24H 24 00 and 12H 12 00 AM PM using Confirm with OK Switch betweenYES and no using Confirm with OK YES activa ted function YES activa ted function Calibration of temperature sensor See previous page no no offset Set point ...

Page 14: ...019 04 03 HH CH Main office Frico AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net ...

Reviews: