SUN12

3

EN

Before operation

• 

Place the dehumidifier in an upright position 

on a stable, flat surface. 

• 

The mains voltage of the dehumidifier is 220-

240VAC and must be connected to an earthed 

outlet socket. 

• 

Ensure the tank is correctly fitted, if the tank 

is full or not in place, the Full tank indicator 

lights up and the dehumidifier stops working.

• 

Turn the unit on and run as per instructions 

on following pages. 

• 

For minimum distances, see diagram.  

 

Continuous drainage 

In general, water will be collected by tank, if you 

want continuous drainage, please do steps as 

follows (see figure 3).

1. 

Remove the water tank.

2. 

Insert the drainage pipe with Ø13mm (1/2”) 

inner diameter through the drainage outlet. 

3. 

Put the water tank back. Make sure the 

pipe is going downhill, and is not blocked or 

kinked. 

Warning

• 

Failure to abide by this warning could result 

in an explosion, death, injury and property 

damage.

• 

Any person who is involved with working on 

or breaking into a refrigerant circuit should 

hold a current valid certificate from an 

industry-accredited assessment authority, 

which authorizes their competence to handle 

refrigerants safely in accordance with an 

industry, recognized assessment specification.

• 

Servicing shall only be performed 

as recommended by the equipment 

manufacturer. Maintenance and repair 

requiring the assistance of other skilled 

Minimum distances

position.

• 

Never use the plug to start and stop the unit. 

Always use switch on the control panel. 

• 

Before moving the unit, first switch off, then 

unplug and empty the water tank.

• 

Do not use flammable cleaners on the unit. 

• 

Never pour or spray water over the unit. 

• 

Component parts are designed for propane 

and non-incentive and non-sparking. 

Component parts shall only be replaced with 

identical repair parts.

• 

If the supply cord is damaged, it must be 

replaced by the manufacturer, its service 

agent or similarly qualified persons in order 

to avoid a hazard.

• 

The unit shall be disconnected from its power 

source during maintenance. 

• 

Ensure the unit is far away from fire, 

inflammable, or explosive objects.

• 

Do not use means to accelerate the 

defrosting process or to clean, other than 

those recommended by the manufacturer.

• 

The unit shall be stored in a room without 

continuously operation sources (for example: 

open flames, an operating gas appliance or 

an operating electric heater).

• 

The unit shall be stored so as to prevent 

mechanical damage from occurring. Do not 

pierce or burn, even after use.

• 

The unit shall be protected from physical 

damage and shall be installed, operated and 

stored in a room with a floor area larger than 

4 m

2

• 

Compliance with national gas regulations 

shall be observed.

• 

Keep any required ventilation openings clear 

of obstruction.

personnel shall be carried out under the 

supervision of the person competent in the 

use of flammable refrigerants. See the safety 

manual "Repair and maintenance - units with 

R290" at www.frico.net.

 

Summary of Contents for Sunnan SUN12

Page 1: ...Sunnan SUN12 Original instructions 1 EN 9 SE 15 NO 21 FR 28 DE 35 NL 42 ES 49 PL 56 RU 63 FI 69 DK...

Page 2: ...and the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away un...

Page 3: ...skilled Minimum distances position Never use the plug to start and stop the unit Always use switch on the control panel Before moving the unit first switch off then unplug and empty the water tank Do...

Page 4: ...aundry drying indicator 17 High fan speed indicator 18 Low fan speed indicator 19 Humidity display 20 Timer indicator 21 Full tank indicator 22 On off indicator 23 Defrost indicator Drainage 24 Draina...

Page 5: ...ithin 5 seconds The timer setting is cancelled if the unit is switched off and then switched on again Press the humidity button to set the humidity from CO 30 35 40 45 50 55 60 65 70 75 80 CO CO means...

Page 6: ...n The timer setting will be kept B Press the power button to switch off the unit and then press the power button to switch it back on The dehumidifier will continue to run in the same mode as before t...

Page 7: ...it with a slightly damp cloth Never spray the unit with water Filter When used regularly the filter may become clogged with dust and particles Therefore the filter should be cleaned at least every two...

Page 8: ...he filter is clogged or the unit is placed on an uneven surface Clean the filter or put the unit on a flat surface The unit does not work The power is not connected Insert the plug into the wall outle...

Page 9: ...e Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net 2022 05...

Reviews: