≥20cm
≥50
cm
≥20
cm
≥20cm
≥20cm
SUN12
3
EN
Before operation
•
Place the dehumidifier in an upright position
on a stable, flat surface.
•
The mains voltage of the dehumidifier is 220-
240VAC and must be connected to an earthed
outlet socket.
•
Ensure the tank is correctly fitted, if the tank
is full or not in place, the Full tank indicator
lights up and the dehumidifier stops working.
•
Turn the unit on and run as per instructions
on following pages.
•
For minimum distances, see diagram.
Continuous drainage
In general, water will be collected by tank, if you
want continuous drainage, please do steps as
follows (see figure 3).
1.
Remove the water tank.
2.
Insert the drainage pipe with Ø13mm (1/2”)
inner diameter through the drainage outlet.
3.
Put the water tank back. Make sure the
pipe is going downhill, and is not blocked or
kinked.
Warning
•
Failure to abide by this warning could result
in an explosion, death, injury and property
damage.
•
Any person who is involved with working on
or breaking into a refrigerant circuit should
hold a current valid certificate from an
industry-accredited assessment authority,
which authorizes their competence to handle
refrigerants safely in accordance with an
industry, recognized assessment specification.
•
Servicing shall only be performed
as recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
Minimum distances
position.
•
Never use the plug to start and stop the unit.
Always use switch on the control panel.
•
Before moving the unit, first switch off, then
unplug and empty the water tank.
•
Do not use flammable cleaners on the unit.
•
Never pour or spray water over the unit.
•
Component parts are designed for propane
and non-incentive and non-sparking.
Component parts shall only be replaced with
identical repair parts.
•
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
•
The unit shall be disconnected from its power
source during maintenance.
•
Ensure the unit is far away from fire,
inflammable, or explosive objects.
•
Do not use means to accelerate the
defrosting process or to clean, other than
those recommended by the manufacturer.
•
The unit shall be stored in a room without
continuously operation sources (for example:
open flames, an operating gas appliance or
an operating electric heater).
•
The unit shall be stored so as to prevent
mechanical damage from occurring. Do not
pierce or burn, even after use.
•
The unit shall be protected from physical
damage and shall be installed, operated and
stored in a room with a floor area larger than
4 m
2
.
•
Compliance with national gas regulations
shall be observed.
•
Keep any required ventilation openings clear
of obstruction.
personnel shall be carried out under the
supervision of the person competent in the
use of flammable refrigerants. See the safety
manual "Repair and maintenance - units with
R290" at www.frico.net.