Installation and operating instructions

General Instructions 

Read these instructions carefully prior to 

installation and use. Keep this manual for future 

reference.

The product may only be used as set out in the 

assembly and operating instructions. The guarantee 

is only valid should the product be used in the 

manner intended and in accordance with the 

instructions. 

Application 

Soloclim is a reversible airconditioner without outdoor 

unit. Soloclim ensures a comfortable room temperature, 

whether you want cooling or heating, at a reduced 

consumption. Protection class: IPX0.  

Soloclim horizontal is designed only for use with R32 

gas as the designated refrigerant, with the exception 

of SC17DCI-MINI which is designed only for use with 

R290 (propane). Both are environmentally friendly 

refrigerant gases, with low or negliable Global Warming 

Potential (GWP). Special precautions must be taken into 

consideration due to the flammability of the refrigerant. 

This unit uses a flammable refrigerant. If 

refrigerant leaks and comes in contact with fire or 

heating part, it will create harmful gas and there 

is risk of fire.  

Only a qualified technician should attempt to 

install and service the unit. Service personnel are 

required to carefully read the user manual and 

the safety manual "Repair and maintenance - 

units with R290/R32/R410a" at www.frico.net.

Safety instructions 

• This appliance can be used by children aged from 8 

years and above and persons with reduced physical, 

sensory or mental capabilities or lack of experience 

and knowledge if they have been given supervision or 

instruction concerning use of the appliance in a safe 

way and understand the hazards involved. Children 

shall not play with the appliance. Cleaning and user 

maintenance shall not be made by children without 

supervision.  

• Children of less than 3 years should be kept away 

unless continuously supervised. 

• Children aged from 3 years and less than 8 years 

shall only switch on/off the appliance provided 

that it has been placed or installed in its intended 

normal operating position and they have been given 

supervision or instruction concerning use of the 

appliance in a safe way and understand the hazards 

involved. 

• Children aged from 3 years and less than 8 years 

shall not plug in, regulate and clean the appliance or 

perform user maintenance.   

• SC21/23DCI: The unit is designed only for use with R32 

gas as the designated refrigerant. 

• SC17DCI-MINI: The unit is designed only for use with 

R290 (propane) gas as the designated refrigerant. 

The refrigerant loop is sealed. Only a qualified 

technician should attempt to service.

• Do not discharge the refrigerant into the atmosphere. 

It is flammable and heavier than air.

The gas first collects in low areas but can be circulated 

by the fans.

• If  gas is present or even suspected, do not allow 

untrained personnel to attempt to find the cause.

• The gas used in the unit has no odor. The lack of smell 

does not indicate a lack of escaped gas.

• If a leak is detected, immediately evacuate all persons 

from the premises, ventilate the premises and contact 

the local fire department to advise them that a gas leak 

has occurred.

• Do not let any persons back into the premises until 

the qualified service technician has arrived and that 

technician advises that it is safe to return.

No open flames, cigarettes or other possible sources of 

ignition should be used inside or in the vicinity of the 

units. 

• After transport or if the unit has been tilted (e.g. during 

cleaning), leave it for an hour before connecting it to 

the mains supply.  

• Always keep the unit in an upright position.

• Never use the plug to start and stop the unit. Always 

use switch on the control panel. 

Do not use flammable cleaners on the unit. 

• Never pour or spray water over the unit. 

• Component parts are designed for the refrigerant and 

non-incentive and non-sparking. Component parts shall 

only be replaced with identical repair parts.

• If the supply cord is damaged, it must be replaced by 

the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard.

• The unit shall be disconnected from its power source 

during maintenance. 

Ensure the unit is far away from fire, inflammable, 

or explosive objects.

• Do not use means to accelerate the defrosting process 

or to clean, other than those recommended by the 

manufacturer.

• The unit shall be installed and stored in a room without 

continuously operation sources (for example: open 

flames, an operating gas appliance or an operating 

electric heater).

• The unit shall be installed and  stored so as to prevent 

mechanical damage from occurring. Do not pierce or 

burn, even after use. 

• SC17DCI-MINI: The unit shall be protected from 

physical damage and shall be installed, operated and 

stored in a room with a floor area larger than 4 m

2

• Compliance with national gas regulations shall be 

observed.

Summary of Contents for Soloclim

Page 1: ...Soloclim Original instructions 11 EN 19 SE 10 NO 12 FR 14 DE 16 NL 18 FI 20 RU 22 PL 24 ES 26 DK...

Page 2: ...Bildern F r die bersetzung der verwendeten Texte in englischer Sprache siehe die entsprechenden Sprachseiten DE Pocz tkowe strony zawieraj g wnie rysunki T umaczenie wykorzystanych tekst w angielskich...

Page 3: ...ke 7 External air outlet 8 Condensate drain tube 0 6 m 9 Anchor bracket 10 Data label 11 Terminal block 12 Air filter 13 Room temperature sensor 14 Internal exchanger 15 External fan 16 Condensation p...

Page 4: ...l mounting bracket D Manual E Remote control Fig 2 Included in delivery F Paper drilling template Fig 4 G CR2025 3V remote control battery H Plastic sheet for wall duct 2 pcs Fig 5 I Energy e ciency l...

Page 5: ...es for M8 plugs B Electrical connection area C 162 mm holes for air ducts Fig 4 Drilling template D 18 mm condensate drain E Hole for anchor bracket F NOT USED SC21DCIN SC23DCIN 1000 A B C D E IN OUT...

Page 6: ...A Chain B Flange C Spring D Outside air grill Fig 5 Air ducts Fig 6 Wall grilles IN OUT IN OUT IN OUT A B C D Plastic sheets for air ducts 6 Soloclim...

Page 7: ...evel 2 Wall bracket 3 Fixing screw 4 Expansion plug 5 Interlocking points Fig 7 Mounting the unit 1 3 2 4 2 5 2 2 5 1 Drainage tube 0 6 m 18 mm outside 13 mm inside 2 Safety drain Fig 8 Drainage 0 1 m...

Page 8: ...ning the unit 3 2 3 1 Wiring diagram GR Grey BR Brown YG Yellow Green BL Blue CP Presence contact N Neutral L Phase IG System main switch PE Earth connection I G L C P G R G R G R B R B L Y E G N N P...

Page 9: ...SCKL Adjustment of deflector changing air flow direction SCSFH1 180 9 Soloclim Accessories Art no Type WxHxD mm 282045 SCKEG162 180x180x20 282046 SCRPK 230x120x170 990547 SCSFH1 940x15x155 999945 SCKL...

Page 10: ...283422 SC23DCIN 3 10 3 05 3 25 3 28 230V 0 65 R32 1010x549x165 41 283423 SC23DCI1000N 3 3 10 0 0 3 25 3 28 230V 0 65 R32 1010x549x165 41 SC17DCI MINI SC21DCIN SC23DCIN SC23DCI1000N Cooling 1 Max cooli...

Page 11: ...ser maintenance SC21 23DCI The unit is designed only for use with R32 gas as the designated refrigerant SC17DCI MINI The unit is designed only for use with R290 propane gas as the designated refrigera...

Page 12: ...d fins are available as accessory Mounting the unit Fig 7 The bracket must be fixed on a level wall surface that is capable of supporting the weight of the unit An inclination of maximum 1 towards the...

Page 13: ...eople from approaching the area igh wall installation The unit can be installed near the floor or higher up on the wall The factory setting is made for low installation with the air flow directed upwa...

Page 14: ...ord pulled from the socket Automatic comfort mode The unit selects cooling or heating mode automatically depending on the set temperature and its fan speed according to the room temperature Setting co...

Page 15: ...cooling and dehumidification mode it resets every 30 minutes to prevent the formation of condensation Setting power The unit has five power settings Minimum Medium Maximum Dual Power and Automatic se...

Page 16: ...dry cloth If it is very dirty use a slightly damp cloth and if necessary a mild detergent Wipe afterwards with a dry cloth to remove moisture Filter Clean the air filter after a period of continuous...

Page 17: ...he heating and or cooling load has increased Cover large windows exposed to sunlight Avoid using halogen lamps or other high energy consumption devices Use the control panel on the unit The remote con...

Page 18: ...of an alarm check that the tube is not bent or obstructed thus preventing the water from flowing out Cooling Dehumidification and Heating modes can still be activated It only monitors the antifreeze f...

Page 19: ...ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net or latest updated information and information a out your local contact www frico net 2022 07...

Reviews: