- If the appliance is not used for a long
period, disconnect it from the power
supply.
Maintenance
Note! When using for the first time or when
starting up after a long period of disuse, a
small amount of smoke and a slight odour
may occur temporarily, which is completely
normal.
During maintenance the heater must be
disconnected from the power supply.
The heater contains no moving parts
and therefore very little maintenance is
required other than to ensure that there is no
excessive build-up of dust/dirt on the reflector
or lamp as this can cause overheating and
premature lamp failure.
To clean the appliance, wipe off with a damp
cloth.
Replacement of lamp
A qualified person shall replace the lamp and
the gaskets.
The lamp is robust and if knocks and shock
vibrations are avoided it will run for a long
time. The expected lifetime of the lamp is
depending on the ambient temperature and
where the heater is installed. When it is
mounted airy and outdoor the lamp will live
longer.
When the lamp is to be replaced the red
silicon gaskets also must be changed. The
gaskets must also be replaced before if there
are signs of aging.
Safety
• During operation the surfaces of the unit
are hot!
• The unit must not be fully or partially
covered with inflammable materials, as
overheating can result in a fire risk!
• This product is not designed to be used
by children or persons with reduced
physical or mental ability or a lack
of experience and knowledge, unless
instruction regarding the product's
use has been given by a person with
responsibility for their safety or that this
person supervises operation. Children
must be kept under supervision to ensure
they do not play with the product.
• The heater is equipped with a protective
grille to prevent contact or to prevent
large objects from touching the hot lamp.
The unit must not be used without this
protective grille.
• Ensure that there are no inflammable
materials gathered on or close to the
heater.
• The free space to the inflammable
material in the direction of radiation
must be at least 1 meter.