AREC3200C

6

Ref Metric

 

[mm]

Imperial

 

[in]

Product type

A

1078

43.12

AREC3210Cx

B

1588

63.52

AREC3215Cx

C

2078

83.12

AREC3220Cx

D

1028

41.12

AREC3210Cx

E

1538

61.52

AREC3215Cx

F

2028

81.12

AREC3220Cx

G

29

1.16

H

90

3.60

I

51

2.04

J

135

5.40

K

70

2.80

L

475

19.00

M

256

10.24

N

525

21.00

B

A

475

525

90
70

256

1, 1,5 m: 4 x M8

2 m: 

6 x M8

90

ø29

ø29

51

135

A / B / C

D / E / F

G

G

J

L

N

M

H

H

K

I

Metric

1 m: 

4 x M8

1.5 m:  4 x M8

2 m: 

6 x M8

Imperial

3.3 ft: 

4 x M8

4.9 ft: 

4 x M8

6.6 ft: 

6 x M8

Summary of Contents for AREC3200C

Page 1: ...Seal The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Prog...

Page 2: ...80V3 10 31 AREC3215CE 480 NA 8 12 2300 73 16 148 0 9 480V3 15 42 AREC3220CE 480 NA 10 16 3250 74 21 254 1 5 480V3 20 59 AREC3210CE 600 NA 5 8 1630 72 9 127 0 8 600V3 8 31 AREC3215CE 600 NA 8 12 2300 7...

Page 3: ...0 1900 74 254 208V 1 5 121 2 Water heat AREC3200CW IP21 1 Highest airflow of totally 3 fan steps 2 Values shown are for total sound power levels for Installation Type A free inlet free outlet The Soun...

Page 4: ...20 48 5 14 4 34 0 17 37 2 AREC3220CW NA max 2550 18 2 41 0 23 27 5 17 9 35 0 22 24 1 Metric chart Imperial chart 1 Recommended outlet air temperature for good comfort and optimized output 2 Nominal ou...

Page 5: ...f pictures For translation of the English texts used see the respective language pages EN Les pages de pr sentation contiennent principalement des images Pour la traduction des textes en anglais consu...

Page 6: ...AREC3210Cx E 1538 61 52 AREC3215Cx F 2028 81 12 AREC3220Cx G 29 1 16 H 90 3 60 I 51 2 04 J 135 5 40 K 70 2 80 L 475 19 00 M 256 10 24 N 525 21 00 B A 475 525 90 70 256 1 1 5 m 4 x M8 2 m 6 x M8 90 29...

Page 7: ...bars outside the unit AREC3220Cx AREC3210Cx AREC3215Cx Front view Side view Ref Metric mm Imperial in Product type A 805 32 20 AREC3210Cx B 1315 52 60 AREC3215Cx C 66 2 64 D 157 6 28 E 933 37 32 F 80...

Page 8: ...AREC3200C 8 Fig 1b Mounting on threaded bars outside the unit Mounting on threaded bars outside the unit Fig 1a Mounting brackets on delivery AREC3220Cx...

Page 9: ...88 Top view Side view AREC3220Cx AREC3210Cx AREC3215Cx E A 851 W 935 121 88 Ref Metric mm Imperial in Product type A 850 34 00 AREC3210Cx B 1360 54 40 AREC3215Cx C 54 2 16 D 124 4 96 E 851 34 04 AREC...

Page 10: ...2c Location of the mounting brackets on the inside of the unit AREC3210Cx AREC3215Cx 4x AREC3220Cx 6x Fig 2d In order to mount the brackets remove the service hatch outlet grille and covering plates A...

Page 11: ...AREC3200C 11 Fig 3a Snap fixings 2 1 1 2 90 AR Service hatch Fig 3b Open the unit Fig 4 Terminal box and control panel inside unit AREC...

Page 12: ...PA34TR20 AREC3220Cx 1 m 3 3 ft PA34CB15 AREC3210Cx AREC3215Cx PA34CB20 AREC3220Cx PA34VD15 AREC3210Cx AREC3215Cx PA34VD20 AREC3220Cx FHDN15 AREC3200CW PA34TR PA34CB PA34VD FHDN15 VKF SD230 Nipple G N...

Page 13: ...4 2 3 1 A L PE N SENSOR 208V1 0 10V Only water N L PE L1 L2 L3 N L PE L1 L2 L3 Blue Yellow Red White M M Left motor Right motor 6 5 4 2 3 1 A L PE N Red 10 V Yellow 0 10 Blue GND White Tach 0 10V DOO...

Page 14: ...b1 L3 L2 L1 a1 a2 b2 c2 c1 b1 C Over heat cut out L1 L2 L3 L3 L1 L2 C3 L1 L2 L3 L3 L1 L2 C4 L3 L2 L1 a1 a2 b2 c2 c1 b1 L3 L2 L1 a1 a2 b2 c2 c1 b1 208V3 0 10V 6 5 4 2 3 1 A L PE N M M Left motor Right...

Page 15: ...TE R WATER PE N L PE C1 L1 L2 L3 C2 C Over he at cut out L1 L2 L3 C3 L1 L2 L3 C4 0 10V PE L1 L2 L3 6 5 4 2 3 1 A L PE N M M Left motor Right motor 6 5 4 2 3 1 A L PE N Blue Yellow Red White Red 10 V Y...

Page 16: ...ler l unit ou d en effectuer l entretien L installation ou l entretien de l unit doivent tre effectu s par un technicien qualifi seulement L unit ne doit pas tre install e et utilis e l ext rieur ou d...

Page 17: ...d bars inside the unit 1 The mounting brackets are fixed to the unit during transport Loosen them and screw them into place inside the unit in the intended holes In order to mount the brackets remove...

Page 18: ...le required Basic setting fan speed The fan speed when the door is open is set using the control Note that the airflow direction and the fan speed may need fine adjustment depending on the loading of...

Page 19: ...the motor temperature has returned to within the motor s operating limits Replacing the water coil W 1 Shut off the water supply to the unit 2 Open the vent valve 3 Open the drain valve 4 When the wa...

Page 20: ...le filter is not dirty If there is no heat check the following The functions internal sensor and settings of the built in control system For units with electrical heating also check the following Powe...

Page 21: ...A2DR Factory setting dip switches Unit with water heating Dip switch 3 is used for PA2DR 2 1 3 Factory setting dip switches Unit without heating or with electrical heating Dip switch 3 is used for PA2...

Page 22: ...lf full power Water On off 1 LED Temperature control If the temperature exceeds 50 C the fan runs at full speed for 2 minutes to vent out the heat if the temperature rises above 50 C again during the...

Page 23: ...o AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico se Art no 189416 K...

Reviews: