Soloclim vertical

14

EN

Troubleshooting 

Action

Cause 

Symptom 

The unit does not work. 

The power is not connected. 

Insert the plug into the wall outlet and push the ON button. 

The filter is clogged. 

Clean the filter.

Make sure the air inlet and outlet are not obstructed. 

The air does not pass freely through 

the unit. 

If the fault cannot be rectified, please contact a qualified service technician. 

There is too much ventilation. 

Reduce ventilation, close doors and windows. 

Check and, if necessary, adjust the temperature settings. 

The desired temperature is set too 

high or too low. 

The cooling or 

heating capacity is not 

adequate. 

The heating and/or cooling load has 

increased. 

Cover large windows exposed to sunlight. Avoid using halogen 

lamps or other high energy consumption devices. 

Use the control panel on the unit. 

The remote control does not work. 

The remote control 

does not work. 

The remote control is not aimed at the 

unit's remote control receiver. 

The distance between the unit and the 

remote control is too large. 

The batteries are dead. 

Make sure that the remote control is close enough to the unit 

and is pointing towards the receiver. 

Change batteries. 

See next page. 

An error code is displayed. 

Check that the system main switch has not been tripped (if it 

has, reset it). If the problem repeats immediately, contact Frico 

Technical support and do not try to make the unit work. 

Check there is power supply (by turning a light on, for 

example). 

Remote control  

The remote control has a working range of approximately 

8 metres. Its top must point towards the display of the 

unit. The reception of the command is confirmed by a 

beep and by the display.  

•  Insert the supplied battery in the remote control before 

operation.  

•  Remove batteries when not in use for an extended 

period in order to preserve battery life.   

•  Always use the same type of batteries when changing 

them. 

Packaging

Packaging materials are chosen with consideration to the 

environment and are therefore recyclable.  

 

Handling of product at end of working life

This product may contain substances necessary for the 

functionality of the product but potentially dangerous for 

the environment. The product should not be disposed of 

mixed with general household waste but delivered to a 

designated collection point for environmental recycling. 

Please contact the local authority for further details of your 

nearest designated collection point. 

Summary of Contents for 999925

Page 1: ...Soloclim vertical Original instructions 9 EN 16 SE 24 NO 32 FR 40 DE 48 NL 56 ES 64 PL 72 RU 80 DK 88 FI...

Page 2: ...tzung der verwendeten Texte in englischer Sprache siehe die entsprechenden Sprachseiten DE Pocz tkowe strony zawieraj g wnie rysunki T umaczenie wykorzystanych tekst w angielskich znajduje si na odpow...

Page 3: ...5 3V remote control battery H Plastic sheet for wall duct 2 pcs Fig 5 I Energy efficiency label J Inside flanges for air inlet and outlet 2 pcs C D A A I F E B G H A J 10 3 3 Soloclim vertical 1 Touch...

Page 4: ...duct C 162 mm hole for inlet air duct D 18 mm condensate drain back E 18 mm condensate drain base F Electrical connection G Holes for anchor bracket H Bottom of the unit I Floor Fig 4 Drilling templa...

Page 5: ...A Chain B Flange C Spring D Outside air grill Fig 5 Air ducts Fig 6 Wall grilles A B C D Plastic sheets for air ducts INSIDE W ALL OUTSIDE W ALL IN OUT IN OUT 5 Soloclim vertical...

Page 6: ...Wall bracket 2 Interlocking points 3 Anchor brackets Fig 7 Mounting the unit 1 Drainage tube 0 6 m 18 mm outside 13 mm inside 2 Safety drain Fig 8 Drainage Fig 8b 2 1 3 1 2 300 mm 3 6 Soloclim vertica...

Page 7: ...ded tape 7 Soloclim vertical Accessories Art no Type WxHxD mm 282045 SCKEG162 180x180x20 282046 SCRPK 230x120x170 Wiring diagram GR Grey BR Brown YG Yellow Green BL Blue CP Presence contact N Neutral...

Page 8: ...COP Voltage V Refrigerant WxHxD mm Weight 2 kg 999925 SCV21DCI 2 04 2 10 2 72 3 10 230V R410a 500x1398x185 57 999926 SCV23DCI 2 35 2 36 2 75 3 15 230V R410a 500x1398x185 57 SCV21DCIN SCV23DCIN Cooling...

Page 9: ...a gas as the designated refrigerant The refrigerant loop is sealed Only a qualified technician should attempt to service Do not discharge the refrigerant into the atmosphere It is flammable and heavie...

Page 10: ...lles use water based paints suitable for plastic surfaces to avoid problems with the movement of the fins Wall grilles with fixed fins are available as accessory Mounting the unit Fig 7 The bracket mu...

Page 11: ...rd In this case appropriate barriers should be installed in order to prevent people from approaching the area 6 Fasten the unit to the upper part of the bracket 7 Verify that the bracket fits securely...

Page 12: ...er cord pulled from the socket Automatic comfort mode The unit selects cooling or heating mode automatically depending on the set temperature and its fan speed according to the room temperature Settin...

Page 13: ...y In cooling and dehumidification mode it resets every 30 minutes to prevent the formation of condensation Setting power The unit has five power settings Minimum Medium Maximum Dual Power and Automati...

Page 14: ...unit and is pointing towards the receiver Change batteries See next page An error code is displayed Check that the system main switch has not been tripped if it has reset it If the problem repeats im...

Page 15: ...vent of an alarm check that the tube is not bent or obstructed thus preventing the water from flowing out Cooling Dehumidification and Heating modes can still be activated It only monitors the antifre...

Page 16: ...ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net 2022 07...

Reviews: