Frico 999925 Original Instructions Manual Download Page 12

Soloclim vertical

12

EN

Control panel

Remote control 

On / off 

Fan mode 

Timer

Hotel function 

Decrease / down 

Increase / up 

Setpoint  

Air deflector  

Automatic comfort mode 

Digital thermometer:

Red bars - heating mode, blue bars - cooling 

mode 

Cooling mode 

Dehumidification mode 

Heating mode

Comfort mode Night

Setpoint   

When the unit is on, the set value is shown on 

the display with three digits. The setpoint value 

can be set between 16 and 31°C. The setpoint 

must not be set too high or low, as this means 

unnecessary energy consumption and reduced 

comfort.  

 

On / off  

The unit can be switched off (standby) or on 

with this button. The system is equipped with a 

memory, which means that the settings will not 

be lost when the unit is turned off or the power 

is switched off. The button is used to switch on or 

off, for short periods.

If the unit is to be switched off for a long time, 

the main switch must be switched off and the 

power cord pulled from the socket.  

 

Automatic comfort mode  

The unit selects cooling or heating mode 

automatically depending on the set temperature 

and its fan speed according to the room 

temperature. 

Setting cooling or heating mode

To deactivate the heating or the cooling mode do 

as follows:

•  Keep the A key on the touch-screen display 

pressed for 10 seconds until HC (heating and 

cooling) appears on the display.

•  Press the A key for 1 second to switch to 

cooling mode (CO).

•  Press the A key again to switch back to heating 

mode (HO).

•  Wait for 3 seconds without touching anything 

to memorise the setting.

 

Cooling mode  

In this mode, the unit dehumidifies and cools 

the room. Use the up/down buttons to set the 

temperature.

The desired temperature can be set between 16 

and 31°C and, if this temperature is lower than 

the room temperature, the compressor starts 

after three minutes (maximum) and the unit 

starts producing cool air, maintaining fan speed 

even if the setpoint has been reached.  

 

Control 

Soloclim is controlled by the touch-screen control panel on the front of the unit or 

by the supplied remote control. 

Setting power

Summary of Contents for 999925

Page 1: ...Soloclim vertical Original instructions 9 EN 16 SE 24 NO 32 FR 40 DE 48 NL 56 ES 64 PL 72 RU 80 DK 88 FI...

Page 2: ...tzung der verwendeten Texte in englischer Sprache siehe die entsprechenden Sprachseiten DE Pocz tkowe strony zawieraj g wnie rysunki T umaczenie wykorzystanych tekst w angielskich znajduje si na odpow...

Page 3: ...5 3V remote control battery H Plastic sheet for wall duct 2 pcs Fig 5 I Energy efficiency label J Inside flanges for air inlet and outlet 2 pcs C D A A I F E B G H A J 10 3 3 Soloclim vertical 1 Touch...

Page 4: ...duct C 162 mm hole for inlet air duct D 18 mm condensate drain back E 18 mm condensate drain base F Electrical connection G Holes for anchor bracket H Bottom of the unit I Floor Fig 4 Drilling templa...

Page 5: ...A Chain B Flange C Spring D Outside air grill Fig 5 Air ducts Fig 6 Wall grilles A B C D Plastic sheets for air ducts INSIDE W ALL OUTSIDE W ALL IN OUT IN OUT 5 Soloclim vertical...

Page 6: ...Wall bracket 2 Interlocking points 3 Anchor brackets Fig 7 Mounting the unit 1 Drainage tube 0 6 m 18 mm outside 13 mm inside 2 Safety drain Fig 8 Drainage Fig 8b 2 1 3 1 2 300 mm 3 6 Soloclim vertica...

Page 7: ...ded tape 7 Soloclim vertical Accessories Art no Type WxHxD mm 282045 SCKEG162 180x180x20 282046 SCRPK 230x120x170 Wiring diagram GR Grey BR Brown YG Yellow Green BL Blue CP Presence contact N Neutral...

Page 8: ...COP Voltage V Refrigerant WxHxD mm Weight 2 kg 999925 SCV21DCI 2 04 2 10 2 72 3 10 230V R410a 500x1398x185 57 999926 SCV23DCI 2 35 2 36 2 75 3 15 230V R410a 500x1398x185 57 SCV21DCIN SCV23DCIN Cooling...

Page 9: ...a gas as the designated refrigerant The refrigerant loop is sealed Only a qualified technician should attempt to service Do not discharge the refrigerant into the atmosphere It is flammable and heavie...

Page 10: ...lles use water based paints suitable for plastic surfaces to avoid problems with the movement of the fins Wall grilles with fixed fins are available as accessory Mounting the unit Fig 7 The bracket mu...

Page 11: ...rd In this case appropriate barriers should be installed in order to prevent people from approaching the area 6 Fasten the unit to the upper part of the bracket 7 Verify that the bracket fits securely...

Page 12: ...er cord pulled from the socket Automatic comfort mode The unit selects cooling or heating mode automatically depending on the set temperature and its fan speed according to the room temperature Settin...

Page 13: ...y In cooling and dehumidification mode it resets every 30 minutes to prevent the formation of condensation Setting power The unit has five power settings Minimum Medium Maximum Dual Power and Automati...

Page 14: ...unit and is pointing towards the receiver Change batteries See next page An error code is displayed Check that the system main switch has not been tripped if it has reset it If the problem repeats im...

Page 15: ...vent of an alarm check that the tube is not bent or obstructed thus preventing the water from flowing out Cooling Dehumidification and Heating modes can still be activated It only monitors the antifre...

Page 16: ...ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net 2022 07...

Reviews: