Frico 74684 Quick Manual Download Page 13

dAtE

-

tHi

21 °C

tLo

18 °C

Prog

HEAt

AL A

-

AL H

-

OFF

-

SEt

-

CLr

-

LAP

-

FC Frico Control - Quick guide

13

EN

Display alarm history. 

Switch off the system. 

To switch off the system, select 

(OFF) using OK. Wait 10 sec.  

The system is then switched on 

by pressing OK and selecting 

(On) with up/down arrow and 

confirming with OK. 

Description 

Default 

settings 

Functions 

Menu 

options

For week program.  

 

Set the following: 

- year 

- month 

- day 

- time (00:00)

For week program. Set the desired room 

temperature (set point temperature) for 

comfort mode. 

For week program. Set the desired room 

temperature (set point temperature) for 

reduced mode. 

Weekly program, see separate section. 

Increase/decrease with up/down 

arrow. Confirm each step with OK. 

Switch between (OFF) and P1-P9 

with up/down arrow. Confirm 

with OK. 

(off) 

(function 

not 

activated)  

Switch heating on/off. 

Switch between (On) and (OFF) 

with up/down arrow. Confirm 

with OK. 

On (on) 

Switch between alarms with up/

down arrow. To see the serial 

number for an alarm, press OK.   

If no alarm: no A.  

Switch between alarms with up/

down arrow. To see the serial 

number for an alarm, press OK.   

If no alarm: no A.  

Factory reset. Resets values to factory 

settings.  

Press OK. Select (YES), by 

keeping OK depressed for 2 

seconds (countdown).  

Change settings, see separate section 

Settings. 

User menu 

Pairing with local access point. Follow set 

up guide in mobile app to pair it with the 

FC system. 

Press OK. A pairing period of 

120 s starts. 

Display active alarm. 

Increase/decrease with up/down 

arrow. Confirm with OK. 

Increase/decrease with up/down 

arrow. Confirm with OK. 

Summary of Contents for 74684

Page 1: ...Control system FC Quick Guide FCDA FC Direct FCSA FC Smart FCPA FC Pro FCBA FC Building EN...

Page 2: ...ensor Local access point for extra sensors and extended range Extra communication cable 5 m Extra communication cable 10 m Extra communication cable 25 m Extra sensor cable 10 m Extra sensor cable 25...

Page 3: ...D GND HI HI LO LO 12V 12V BUS 1 BUS 2 PE L N 230V G 1 2 Sensor GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V Control Panel Sensor FCRTX FCOTX D1 D2 WTA Actuator 24V E1 E2 Com NO NC BLK GRY RED G 1 2 Sensor...

Page 4: ...AP Set up in Setup Guide FCDC SDM VPFC VMFC FCWTA Config input PC Board inside air curtain A1 A2 B1 B2 GND GND GND GND HI HI LO LO 12V 12V BUS 1 BUS 2 PE L N 230V G 1 2 Sensor GND HI LO 12V BUS 1 BUS...

Page 5: ...HI LO 12V BUS 1 BUS 2 GND HI LO 12V Control Panel Sensor FCRTX FCOTX D1 D2 WTA Actuator 24V E1 E2 FCDC Com NO NC FCWTA BLK GRY RED SDM VPFC VMFC GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V FCLAP Config in...

Page 6: ...GND GND GND GND HI HI LO LO 12V 12V BUS 1 BUS 2 PE L N 230V G 1 2 Sensor GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V Control Panel Sensor FCRTX FCOTX D1 D2 WTA Actuator 24V E1 E2 Com NO NC BLK GRY RED S G...

Page 7: ...erference the communication BUS should be terminated at each end i e in the units that are located at the start and at the end of the BUS respectively On delivery all buses are pre connected with a 12...

Page 8: ...mation FCOTX FCTXRF outdoor temperature signal in FCBAP heating is automatically blocked when the outdoor temperature exceeds 15 C The set point can be changed and this function can be deactivated see...

Page 9: ...ay the set point temperature The FC control is delivered with preset values The preset set point temperature is 21 C and can be easily adjusted using the up down arrows Normal mode Comfort mode Comfor...

Page 10: ...n speed 0 100 Auto 0 3 Auto Auto requires outdoor temperature information FCOTX FCTXRF outdoor temperature signal in FCBAP Fan menu Browse between the menu options Confirm Home screen Press twice to a...

Page 11: ...closes Increase decrease with up down arrow Confirm with OK Increase decrease with up down arrow Confirm with OK Increase decrease with up down arrow Confirm with OK Fan speed if there is a need for...

Page 12: ...Quick guide 12 EN User menu See the table on the following page for the possible choices Press to activate keypad Confirm Exit without saving or Press and hold for 2 seconds Browse between the menu op...

Page 13: ...arrow Confirm each step with OK Switch between OFF and P1 P9 with up down arrow Confirm with OK off function not activated Switch heating on off Switch between On and OFF with up down arrow Confirm wi...

Page 14: ...temporary set point temperature Confirm The temporary set point temperature will apply until the next program step Power failure Note A power loss longer than 7 days may require an adjustment of time...

Page 15: ...ted 1 function activated Automatic time change over Press to activate keypad Press and hold for 2 seconds After run speed fixed Fan speed in fixed after run mode After run speed Auto low Low fan speed...

Page 16: ...1 enabled Outdoor temperature heat blocking set point Set point for Outdoor temperature heat blocking in 0 1 C Block water bypass due to outdoor temperature 0 disabled 1 enabled If enabled the water...

Page 17: ...ed Controls the return water temperature Requires return water temperature sensor and mobile app Return water temperature set point Requires return water temperature sensor and mobile app Actuator exe...

Page 18: ...nsor fault Fault on the control panel s temperature sensor Incorrect sensor connection Outdoor temperature sensor fault Error code Action Cause Control panel communication error Reset alarm To reset m...

Page 19: ...cal supply Check the overheat protection see manual for the air curtain Clean the filter Reset the alarm manually Replace the batteries A 35 A 36 A 37 A 38 A 39 A 33 BMS communication error BMS invali...

Page 20: ...08 EV CH Main o ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www f...

Reviews: