Frico 74680 Original Instructions Manual Download Page 5

FC111/113

5

FCBC05/10/25 
FCSC10/25

FCPOBH / FCPOB3H

FCBC10

FCBB

FCRTX

FCOTX

FCSC10

FCSC10

FCSC10

Typ

Beskrivning

HxBxD 
[mm]

FCPOBH

Styrenhet för systemutbyggnad, 16A, 230V~/400V2~, FC111, IP44

105x105x38

FCPOB3H

Styrenhet för systemutbyggnad, 3x13A, 400V3~, FC113, IP44

149x149x43

FCBB

Svartkroppsgivare, IP44

89x89x43

FCRTX

Extern rumstemperaturgivare, IP20

39x39x23

FCOTX

Utetemperaturgivare, IP44

39x39x23

FCBC05

Extra kommunikationskabel, 5 m

L: 5 m

FCBC10

Extra kommunikationskabel, 10 m

L: 10 m

FCBC25

Extra kommunikationskabel, 25 m

L: 25 m

FCSC10

Extra givarkabel, 10 m

L: 10 m

FCSC25

Extra givarkabel, 25 m

L: 25 m

Tillval

SE  

Type

Beskrivelse

HxBxD 
[mm]

FCPOBH

Styreenhet for systemutbygging, 16A, 230V~/400V2~, FC111, IP44

105x105x38

FCPOB3H

Styreenhet for systemutbygging, 3x13A, 400V3~, FC113, IP44

149x149x43

FCBB

Black bulb sensor, IP44

89x89x43

FCRTX

Ekstern romtemperaturføler, IP20

39x39x23

FCOTX

Utetemperaturføler, IP44

39x39x23

FCBC05

Ekstra kommunikasjonskabel, 5 m

L: 5 m

FCBC10

Ekstra kommunikasjonskabel, 10 m

L: 10 m

FCBC25

Ekstra kommunikasjonskabel, 25 m

L: 25 m

FCSC10

Ekstra giverkabel, 10 m

L: 10 m

FCSC25

Ekstra giverkabel, 25 m

L: 25 m

Ekstrautstyr

NO  

Type

Description

HxWxD 
[mm]

FCPOBH

Control box for system extension, 16A, 230V~/400V2~, FC111, IP44

105x105x38

FCPOB3H

Control box for system extension, 3x13A, 400V3~, FC113, IP44

149x149x43

FCBB

Black bulb sensor, IP44

89x89x43

FCRTX

External room temperature sensor, IP20

39x39x23

FCOTX

Outdoor temperature sensor, IP44

39x39x23

FCBC05

Extra communication cable, 5 m

L: 5 m

FCBC10

Extra communication cable, 10 m

L: 10 m

FCBC25

Extra communication cable, 25 m

L: 25 m

FCSC10

Extra sensor cable, 10 m

L: 10 m

FCSC25

Extra sensor cable, 25 m

L: 25 m

Options

GB  

Summary of Contents for 74680

Page 1: ...Control system FC 6 SE 13 NO Original instructions Standalone level FC111 FC113 20 GB...

Page 2: ...30V G 1 2 GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V FCPOBH Sensor FCCH G 1 2 Sensor Max 16A Sensor FCBB FCRTX FCOTX L2 L2 PE PE LIN LOUT N N A1 A2 B1 B2 GND GND GND 0 10V OUT GND GND HI HI LO LO 12V 12V...

Page 3: ...v till resistans kan termineringsswitchen p kortet s ttas i l ge ON SE NO GB To reduce the risk of interference the communication BUS should be terminated at each end i e in the units that are located...

Page 4: ...Inng r i Beskrivelse HxBxD mm FCCH FC111 FC113 Kontrollpanel IP44 89x89x26 FCPOBH FC111 Styreenhet 16A 230V 400V2 IP44 105x105x38 FCPOB3H FC113 Styreenhet 3x13A 400V3 IP44 149x149x43 FCBC05 FC111 FC1...

Page 5: ...ystemutbygging 3x13A 400V3 FC113 IP44 149x149x43 FCBB Black bulb sensor IP44 89x89x43 FCRTX Ekstern romtemperaturf ler IP20 39x39x23 FCOTX Utetemperaturf ler IP44 39x39x23 FCBC05 Ekstra kommunikasjons...

Page 6: ...lb sensor With black bulb sensors the operative temperature is measured and the control adapted to suit radiant heaters When the black bulb sensors are connected accessory FCBB the system will automat...

Page 7: ...ng Colour LED Operating mode Indicator Operating Mode left hand LED During start up the text Inlt appears on screen then the current room temperature is displayed When the screen is in standby mode th...

Page 8: ...r d day Set the desired time Set the desired room temperature set point temperature Confirm Press to activate keypad Press to start timer at the preset values 1 h 24 C or the most recently used values...

Page 9: ...am see separate section Increase decrease with up down arrow Confirm each step with OK Increase decrease with up down arrow Confirm with OK Increase decrease with up down arrow Confirm with OK Switch...

Page 10: ...fort mode Other times Reduced night mode Residence late Residence short Shop late Shop Weekend Residence day only Office Office late Mon Sun Mon Fri Mon Fri Mon Fri Sat Sun Fri Sat Sun Mon Fri Sat Sun...

Page 11: ...1 function activated See weekly program 1 function activated 0 function not activated 1 function activated 900 sec 300 6000 sec 1 function activated 0 function not activated 1 function activated Heati...

Page 12: ...t lost with black bulb sensor External room temperature sensor fault Fault on the control panel s temperature sensor Incorrect sensor connection Outdoor temperature sensor fault Black bulb sensor faul...

Page 13: ......

Page 14: ...19 04 03 HH CH Main of ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contac...

Reviews: