Frico 74680 Original Instructions Manual Download Page 3

FC111/113

3

FC113

GN

D

GN

D

HI

HI

LO

LO

+12V

+12V

BUS 1

BUS 2

GN

D

GN

D

HI

HI

LO

LO

+12V

+12V

BUS 1

BUS 2

GN

D

GN

D

HI

HI

LO

LO

+12V

+12V

BUS 1

BUS 2

400V3~

FC111/113 - FCPOBH/FCPOB3H

A1 A2

B1 B2

GND

GND

GND

0-10V OU

T

GN

D

GN

D

HI

HI

LO

LO

+12V

+12V

BUS 1

BUS 2

G 1 2

GND

HI

LO

+12V

BUS 

1

BUS 

2

GND

HI

LO

+12V

FCPOB3H

Sensor

FCCH

G 1 2

Sensor

Sensor

FCBB

FCRTX

FCOTX

N N

U V W

L1

L3 L2

400V 3N~

PE PE

Max 3x13A

För att minska risken för störningar ska kommunikationsbussen vara terminerad (avslutad) i 
vardera änden dvs. i de enheter som sitter i början respektive i slutet av bussen. Vid leverans 
är alla bussar förterminerade med ett 120 Ohms motstånd mellan HI and LO på BUS2. Vid 
vidarekoppling tas motståndet bort. 
Som alternativ till resistans kan termineringsswitchen på kortet sättas i läge ”ON”. 

SE  

NO  

GB  

To reduce the risk of interference, the communication BUS should be terminated at each end, i.e. in 
the units that are located at the start and at the end of the BUS respectively. On delivery, all buses 
are pre-connected with a 120 Ohm resistor between terminals HI and LO on BUS2. When making 
further connections, remove the resistor. 
As an alternative to resistance, the termination switch on the board can be set to the "ON" position. 

For å redusere faren for forstyrrelser skal kommunikasjonsbussen være terminert (avsluttet) i 
hver ende, dvs. i de enhetene som er plassert i begynnelsen henholdsvis i slutten av bussen. Ved 
levering er alle busser på forhånd terminert med en motstand på 120 Ohm mellom HI og LO på 
BUS2. Ved viderekobling fjernes motstanden. 
Som alternativ til resistans kan termineringssvitsjen på kortet settes i stillingen ”ON”. 

Summary of Contents for 74680

Page 1: ...Control system FC 6 SE 13 NO Original instructions Standalone level FC111 FC113 20 GB...

Page 2: ...30V G 1 2 GND HI LO 12V BUS 1 BUS 2 GND HI LO 12V FCPOBH Sensor FCCH G 1 2 Sensor Max 16A Sensor FCBB FCRTX FCOTX L2 L2 PE PE LIN LOUT N N A1 A2 B1 B2 GND GND GND 0 10V OUT GND GND HI HI LO LO 12V 12V...

Page 3: ...v till resistans kan termineringsswitchen p kortet s ttas i l ge ON SE NO GB To reduce the risk of interference the communication BUS should be terminated at each end i e in the units that are located...

Page 4: ...Inng r i Beskrivelse HxBxD mm FCCH FC111 FC113 Kontrollpanel IP44 89x89x26 FCPOBH FC111 Styreenhet 16A 230V 400V2 IP44 105x105x38 FCPOB3H FC113 Styreenhet 3x13A 400V3 IP44 149x149x43 FCBC05 FC111 FC1...

Page 5: ...ystemutbygging 3x13A 400V3 FC113 IP44 149x149x43 FCBB Black bulb sensor IP44 89x89x43 FCRTX Ekstern romtemperaturf ler IP20 39x39x23 FCOTX Utetemperaturf ler IP44 39x39x23 FCBC05 Ekstra kommunikasjons...

Page 6: ...lb sensor With black bulb sensors the operative temperature is measured and the control adapted to suit radiant heaters When the black bulb sensors are connected accessory FCBB the system will automat...

Page 7: ...ng Colour LED Operating mode Indicator Operating Mode left hand LED During start up the text Inlt appears on screen then the current room temperature is displayed When the screen is in standby mode th...

Page 8: ...r d day Set the desired time Set the desired room temperature set point temperature Confirm Press to activate keypad Press to start timer at the preset values 1 h 24 C or the most recently used values...

Page 9: ...am see separate section Increase decrease with up down arrow Confirm each step with OK Increase decrease with up down arrow Confirm with OK Increase decrease with up down arrow Confirm with OK Switch...

Page 10: ...fort mode Other times Reduced night mode Residence late Residence short Shop late Shop Weekend Residence day only Office Office late Mon Sun Mon Fri Mon Fri Mon Fri Sat Sun Fri Sat Sun Mon Fri Sat Sun...

Page 11: ...1 function activated See weekly program 1 function activated 0 function not activated 1 function activated 900 sec 300 6000 sec 1 function activated 0 function not activated 1 function activated Heati...

Page 12: ...t lost with black bulb sensor External room temperature sensor fault Fault on the control panel s temperature sensor Incorrect sensor connection Outdoor temperature sensor fault Black bulb sensor faul...

Page 13: ......

Page 14: ...19 04 03 HH CH Main of ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contac...

Reviews: