Step»15:
It is important to reset the
control box by holding the
down button (V) on the
control panel for up to 10
seconds. The desk is now
ready for use.
FIRST TIME USE:
TO PROGRAM THE MEMORY CONTROL PANEL:
TO SET THE MINIMUM/MAXIMUM HEIGHT LIMITS
Adjust the table to the desired height, press the
S
key and one of the three
preset buttons. This position is now saved. Once a preset button is pushed, the
table will automatically move to the preset height. Repeat this procedure for
each preset button.
This base is designed to go to its minimum and maximum heights, allowing for the
widest possible range. If you prefer to change the setting s to a more narrow range,
follow these steps:
Make sure the power is ON and a number reads in the LED display (if no number
appears, please follow the Reset procedure described in step 15).
To»set»the»Upper-Limit»Position:
#1. Use the UP/Down buttons to move the base to the desired maximum height
position. #2 Press and hold the “S” button until the LED display flashes “S-“ once
and let go of the button. #3 Then press and release the button 2 more times in quick
succession. LED display will change to “999”, and then automatically return to the
selected height. The upper limit is now set.
To»Set»the»Lower-Limit»Position:
Use the UP/DOWN buttons to move the base to the desired minimum height position.
Press and hold the “S” button until the LED display flashes “S-“ once and let go of the
button. Then press and release the button 2 more times in quick succession. The LED
display will change to “000” on the third push and then automatically return to the
selected height. The lower limit is now set.
To»reset»the»Upper/Lower»Limit»Position:
Use the UP or DOWN button to move the desk to any new positon. Press and hold
the “S” button until the LED display flashes “S-“ once and let go of the button. Then
press and release the button in succession x6 until the display changes to “555”. After
a few seconds, the display automatically will change back to the numbered height
positon. The upper and lower limits are now removed.
Note:
After the upper and lower limits are set, the previous memory positions (1, 2,
and 3) may be outside the new range of movement. If so, simply reset the memory
positions.
Note:
A reset procedure requires adjusting the base to the lowest position. Please
ensure that you allow the proper clearance below the desk base.
Note:
If you attempt to revise a previously set upper or lower limit and it is outside
the existing range, you need to remove the previously set upper/lower limits first.
Note:
The minimum and maximum height range can be adjusted as often as needed.
Be sure to follow the reset process before setting new minimum/maximum height