Step»17:
It is important to perform the
reset operation below before
you use your My-Hite table
for the first time.
FIRST TIME USE:
SET MINIMUM HEIGHT
RESET OPERATION
CLEAR MAXIMUM & MINIMUM HEIGHT
SET MAXIMUM HEIGHT
1.
Press the arrow up (V) button to get to desired minimum height.
»
Note:»the»arrow»up»button»must»be»the»last»button»pressed»to»set»the»minimum»height.»You»
cannot»press»the»arrow»down»button»when»trying»to»set»the»minimum»height.
2.
Hold “S” button til screen display flashes. Immediately press “S” button twice
again.
3.
Display will flash “000” and then show the set minimum height.
1.
Lower the table to 24.5” by holding arrow down (V) button. Release button.
2.
Press the arrow down (V) button again and hold til ASR shows on the display.
3.
Release the button and the ASR will flash on the display
4. Hold the arrow down button again. Table will shift up and down slightly as it
resets to 24.5”.
V
1.
Press the arrow up ( ) button to get to desired maximum height.
»
Note:»the»arrow»up»button»must»be»the»last»button»pressed»to»set»the»maximum»height.»
You»cannot»press»the»arrow»down»button»when»trying»to»set»the»maximum»height.
2.
Hold “S” button til screen display flashes. Immediately press “S” button twice
again.
3.
Display will flash “999” and then show the set maximum height.
1.
Table can be at
ANY HEIGHT
but
NOT
the minimum or maximum.
2.
Hold “S” til display flashes. Release button.
3.
Press “S” slowly, multiple times - until “555” shows on display.
Note:
Display will show other codes, continue to press “S” until “555” shows.
4. Display will then show table height and can now move to any height between
24.5” and 50.1”.
NOTE:
»If»you»cannot»lower»the»table»to»the»24.5”»height»to»perform»reset»
operation,»you»may»need»to»clear»out»the»maximum»and»minimum»height»
(See»instructions»below).»Once»completed,»please»return»to»the»Reset»
Operation»instructions.
TROUBLESHOOTING MY-HITE
Error»code
Explanation
Cause
Solution
H01
Motor has
overheated
Overuse
1.
Let motor rest of 10 minutes
2.
Perform reset operation
if problem persists
3.
contact Friant customer service
ASR or
RST (solid
or flashing)
System is
locked
Various Reasons
1.
Remove plug from electrical outlet for 15
seconds, then plug unit back in
2.
Perform reset operation
if problem persists
3.
contact Friant customer service to
replace control panel
No display
Control
Panel has
lost power
Disruption in
power supply to
base
1.
Remove plug from electrical outlet for 15
seconds, then plug unit back in
2.
Perform reset operation
if problem persists
3.
contact Friant customer service to
replace control panel
E01,
E02, or
E03
Excessive
weight
distribution
Too much
weight (limit
exceeded)
or
Other problem
1.
Check that weight on table does not
exceed limit
2.
Perform reset operation
if problem persists
3.
contact Friant customer service to
replace control panel
E07,
E08, or
E09
Signal
Interruption
Signal is
interrupted
between leg
and computer
1.
Perform reset operation
if problem persists
2.
contact Friant customer service
Follow assembly instructions closely
Do not overload the tables (220 lbs maximum straight, 330 lbs maximum
corner)
The input voltage should be within 108-132V
Use the glides to properly level the table before use
When moving the table, do not tilt the table on one leg or misalignment may
occur
Before first use, perform reset operation
If, after trouble shooting the problem persists, contact Customer Service for
further assistance.
GENERAL TIPS