background image

REMOVAL AND REPLACEMENT OF PARTS

Page 8

Service Manual Hot Deli Two Tier HDTT3/4/5/7   form 9124303   rev.06/2018

WARNING:

 

Disconnect the electrical power to the machine 

at the main circuit box. Place a tag on the circuit box indica-
ting the circuit is being serviced.

1.  Open the middle door with the special 

key.

2.  Loosen the bolt of the next (adjacent) 

panel. 

3.  Turn the panel open.
4.  Reverse the procedure to install.

Note:

 The panels can be lifted out from the 

hinges. First lift out the hinge on the middle 
panel.

1.  Open the middle door with the special 

key.

2.  Remove the screws that secure the cover 

plate and turn cover plate towards  
yourself.

3.  Remove the 2 bolts that secure the 

mounting plate and remove this plate.

4.  Disconnect the wiring from the fuse 

housing.

5.  Remove the flat nut that secures the 

housing of the fuse and remove the  
housing.

6.  Reverse the procedure to install.

REMOVAL AND REPLACEMENT OF PARTS 

PANELS BACK SIDE

FUSE AND FUSE HOLDER

Summary of Contents for HOT DELI Two Tier 3

Page 1: ...passing If you have not attended training for this product you should read in its entirety the repair procedure you wish to perform to determine if you have the necessary tools instruments and skills...

Page 2: ...Page 2 TABLE OF CONTENTS Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 EMPTY PAGE...

Page 3: ...3 TABLE OF CONTENTS Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 Versions Version Issue date dd mm yy Remarks 10 2016 01 10 2016 First release 06 2018 01 06 2018 Update flap d...

Page 4: ...per 14 Electrical tests and service procedures 15 Heating element test 15 Adjusting Danfoss ERC 211 thermostat 16 Danfoss ERC 211 Settings 17 Control location Two Tier 18 Troubleshooting 19 Hot Deli T...

Page 5: ...Page 5 TABLE OF CONTENTS Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 EMPTY PAGE...

Page 6: ...on available at the time of printing TECHNICAL DATA Type HD 3 HD 4 HD 5 HD 7 Power W 4000 4300 4600 8300 Fuses needed with power connection 400V 3N 50 60Hz 3 phases with zero 3x 16 A 3x 16 A 3x 16 A 3...

Page 7: ...on off the Merchandiser with the main switch on the backside Check set temperature The temperature in the warmer is shown on the display during use 1 Press SET key The set temperature will be shown o...

Page 8: ...en 4 Reverse the procedure to install Note The panels can be lifted out from the hinges First lift out the hinge on the middle panel 1 Open the middle door with the special key 2 Remove the screws tha...

Page 9: ...cure the mounting bracket on the blower 7 Remove the blower by sliding this towards yourself 8 Reverse the procedure to install Note For the blower on the right hand side skip step 4 Note 2 The blower...

Page 10: ...nuts and rings that secure the element and remove the element 6 Reverse the procedure to install Note For the heating element on the right hand side skip step 2 HEATING ELEMENT LEFT AND RIGHT HAND SI...

Page 11: ...move the thermo stat 4 Disconnect the wiring 5 Reverse the procedure to install Note Set all parameters in the new thermo stat THERMOSTAT DANFOSS ERC 211 CERAMIC ELEMENT 1 Remove the socket head screw...

Page 12: ...L 1 Turn the front glass to the top position 2 Remove the screw on the bottom side of the gas spring 3 Remove the pin out of the gas spring Be aware of supporting the glass 4 Loosen the adjusting scre...

Page 13: ...pring Be aware of supporting the glass 4 Remove the 2 screws on the top side and remove the gas spring 5 Also remove the gas spring on the other side 6 Take out the front glass and place this on a tab...

Page 14: ...Page 14 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 PROTECTION PROFILE IN FRONT BUMPER 1 Remove the profile with a screw driver Slide screw driver over the length to remove t...

Page 15: ...tance F C 10 Ohms 60 16 930 70 21 970 80 27 1016 90 32 1056 100 38 1107 125 52 1227 150 65 1347 200 94 1636 250 121 1935 1 Remove the right side panel according prior procedure 2 Remove the wiring fro...

Page 16: ...D SERVICE PROCEDURES Page 16 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 ADJUSTING DANFOSS ERC 211 THERMOSTAT In order to adjust the thermostat first open the panel on the ba...

Page 17: ...Minimum cut in voltage 0 V A74 Minimum cut out voltage 0 V A75 Maximum voltage 270 V d01 Defrost method no no defrost nAt natural no d02 Defrost stop temperature 6 C d03 Defrost Interval 8 hr d04 Max...

Page 18: ...n switch If the elements are switched on the indicator lamp A1 will go on Error codes on display E29 PT sensor broken or wiring problem sensor A01 High temperature alarm A02 Low temperature alarm A99...

Page 19: ...malfunction 4 Wiring loose Display does not reach desired tempera ture 1 Incorrect line voltage 2 PTC 1000 sensor malfunction 3 Heater s inoperative 4 Blower motor s inoperative 5 Contactor inoperati...

Page 20: ...23 29 26 22 7 9 5 5 1 12 20 11 16 13 15 14 19 18 14 1 1 52 5 3 5 4 5 5 5 2 5 6 5 7 4 6 4 7 4 2 4 5 51 2 1 3 1 4 1 5 1 2 32 4 3 4 4 1 28 27 10 17 44 44 48 49 47 47 46 45 50 EXPLODED VIEWS AND PARTLISTS...

Page 21: ...s 3 Window 10 All models 4 Window 10 All models 5 Window 11 HD 3 3 Handle 11 HD 4 4 Handle 11 HD 5 5 Handle 12 HD 3 3 Hinge profile 12 HD 4 4 Hinge profile Item Part number Model Qty Description 12 HD...

Page 22: ...els 1 Back panel switch 31 9267045 All models 1 Back panel for lock 32 9267044 HD 3 1 Back panel 32 9267044 HD 4 2 Back panel 32 9267044 HD 5 3 Back panel 33 9261702 All models 1 Key for lock 34 92617...

Page 23: ...S AND PARTLISTS Page 23 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 6 2018 Item Part number Model Qty Description 10 20 9260296S HD 3 HD 4 HD 5 1 Flap door complete with profiles and...

Page 24: ...69 71 65 64 62 63 61 75 74 72 73 82 81 78 77 79 80 76 70 71 EXPLODED VIEWS AND PARTLISTS Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 6 2018 Page 24 HOT DELI TWO TIER 3 4 5 7 SQUARE...

Page 25: ...l 67 9267264 HD 5 4 Bracket price rail 68 4311110 HD 3 3 Washer M5x1 2 SS 68 4311110 HD 4 4 Washer M5x1 2 SS 68 4311110 HD 5 5 Washer M5x1 2 SS 69 4285408 HD 3 3 Nut M5x10 domed cap 69 4285408 HD 4 4...

Page 26: ...102 1 101 100 99 102 98 95 94 93 96 97 91 92 90 111 110 108 112 112 113 EXPLODED VIEWS AND PARTLISTS Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 6 2018 Page 26 HOT DELI TWO TIER 3 4...

Page 27: ...ights 98 9267113 HD 3 2 Bracket for grid 98 9267113 HD 4 3 Bracket for grid 98 9267113 HD 5 4 Bracket for grid 99 9267129 All models 2 Mounting plate electrical components Item Part number Model Qty D...

Page 28: ...EXPLODED VIEWS AND PARTLISTS Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 6 2018 Page 28 HOT DELI TWO TIER 3 4 5 7 SQUARE TC UNDERFRAME...

Page 29: ...HD3 1 Bottom shelf 122 9267202 HD4 1 Bottom shelf 122 HD5 1 Bottom shelf 123 9264409 All models 2 Panel 124 9264406 All models 4 Mounting profile for legs 125 9261012 All models 8 Adjustable leg 126...

Page 30: ...ELECTRICAL DIAGRAMS Page 30 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 ELECTRICAL DIAGRAMS CIRCUIT DIAGRAM HDTT 3 SQUARE TC...

Page 31: ...T2 6T3 14NO 22 23 1 2 3 4 5 6 16 15 18 17 8 9 6 7 13 5 14 12 37 36 39 38 44 45 46 47 40 41 42 43 19 20 21 22 BN BU 4N 3L 2 1 9 10 11 4 11 13 5 28 29 26 27 52 47 46 24 25 45 44 40 41 42 43 32 33 31 30...

Page 32: ...ELECTRICAL DIAGRAMS Page 32 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 CIRCUIT DIAGRAM HDTT 7 SQUARE TC...

Page 33: ...47 45 44 62 63 32 33 30 31 34 35 81 1 3 2 7 10 80 83 84 G N L3 L2 L1 8T4 6T3 4T2 2T1 1L1 3L2 5L3 7L4 A2 A1 21 36 10 20 37 39 112 11 38 19 18 16 23 31 15 114 14 17 25 12 1 2 3 4 5 110 109 107 101 103...

Page 34: ...ELECTRICAL DIAGRAMS Page 34 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 CIRCUIT DIAGRAM HDTT 4 SQUARE...

Page 35: ...28 29 82 26 27 62 63 32 33 30 31 34 35 81 1 3 2 7 10 80 81 82 G N L3 L2 L1 8T4 6T3 4T2 2T1 1L1 3L2 5L3 7L4 A2 A1 21 36 20 37 19 39 11 38 18 23 31 15 14 17 25 12 1 2 3 4 5 16 9 10 1 2 3 4 5 6 1 4 2 3...

Page 36: ...Page 36 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 EMPTY PAGE...

Page 37: ...Page 37 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 EMPTY PAGE...

Page 38: ...38 Service Manual Hot Deli Two Tier HDTT3 4 5 7 form 9124303 rev 06 2018 Fri Jado B V P O Box 560 4870 AN Etten Leur The Netherlands tel 31 76 50 85 400 fax 31 76 50 85 444 info frijado com www frijad...