ELECTRICAL TESTS AND SERVICE PROCEDURES
Service Manual Hot Deli HD3/4/5/7 form 9123549 rev.03/2017
Page 32
WARNING:
Disconnect the electrical power to the machine
at the main circuit box. Place a tag on the circuit box indica-
ting the circuit is being serviced.
ELECTRICAL TESTS AND SERVICE PROCEDURES
PT 1000 SENSOR TEST PREMIUM (HUMIDIFIED VERSION)
1. Remove the right side panel according prior procedure.
2. Remove the wiring from the sensor.
3. Connect a temperature sensor to the probe for comparison.
4. Test the probe with an Ohmmeter.
Temperature
Resistance Ω
°F °C
± 5 Ohms
60
16
1062
70
21
1082
80
27
1106
90
32
1124
100
38
1148
125
52
1202
150
65
1252
200
94
1362
250
121
1464
350
177
1674
450
233
1880
Temperature
Resistance
°F °C
± 10 Ohms
60 16
930
70 21
970
80 27
1016
90 32
1056
100 38
1107
125 52
1227
150 65
1347
200 94
1636
250 121
1935
1. Remove the right side panel according
prior procedure.
2. Remove the wiring from the sensor.
3. Connect a temperature sensor to the
probe for comparison.
4. Test the probe with an Ohmmeter.
PTC 1K SENSOR TEST (ESSENTIAL AND SELF SERVICE VERSION)
Summary of Contents for HOT DELI 3
Page 2: ...Service Manual Hot Deli HD3 4 5 7 form 9123549 rev 04 2017 Page 2 TABLE OF CONTENTS EMPTY PAGE...
Page 7: ...Service Manual Hot Deli HD3 4 5 7 form 9123549 rev 04 2017 Page 7 TABLE OF CONTENTS EMPTY PAGE...
Page 122: ...Service Manual Hot Deli HD3 4 5 7 form 9123549 rev 03 2017 Page 122 EMPTY PAGE...
Page 123: ...Service Manual Hot Deli HD3 4 5 7 form 9123549 rev 03 2017 Page 123 EMPTY PAGE...