background image

CC 

 Cold

 

US 

22/24 

Notes.  

 

Summary of Contents for Cold FS 100

Page 1: ...CC Cold US EN Original Instruction 9124780 2210 USER MANUAL Custom Counter Cold US Version WARNING Read the instructions before using the machine...

Page 2: ...s a result of constant commitment to improvement it may happen that your unit deviates in detail from what is described in this manual For this reason the given instructions are only a guideline for t...

Page 3: ...2 DESCRIPTION OF THE UNIT 8 2 1 Technical description 8 2 2 Intended use 8 2 3 Accessories 9 3 INSTALLATION AND FIRST USE 10 3 1 Unpacking the unit 10 3 2 Installation and positioning 10 3 3 First us...

Page 4: ...ne and contains the following data Name of the supplier or the manufacturer Model Serial number Year of construction Voltage Frequency Power consumption 1 3 Pictograms and symbols In this manual the f...

Page 5: ...uctions and regulations The pictograms labels instructions and warning signs attached to the unit are part of the safety measures They may never be covered or removed and have to be clearly visible du...

Page 6: ...hat any refrigerant released from the system during its operation cannot cause harm to the user of the appliance The aperture shall be located so that it is unlikely to be obstructed in normal use The...

Page 7: ...low these instructions Clean the unit thoroughly Wrap the unit from getting dusty Store the unit in a dry non condensing environment Ensure good ventilation Humidification by Carel Humisonic empty wat...

Page 8: ...sensitive foodstuffs such as fresh meat or fish The Custom Counter ColdPrep is an assisted self serve refrigerated display cabinet intended for chilled presentation and preparation of packaged and un...

Page 9: ...CC Cold US 9 24 2 3 Accessories Your unit contains the following standard accessories User manual For optional accessories contact customer service frijado com...

Page 10: ...cal shock or other personal injury Failure to follow these instructions can result in death or serious injury WARNING Position the unit on a flat and horizontal surface A temporally inclined plane of...

Page 11: ...F Default set values are Ice Cold 31 1 F Fresh Cold 34 7 F Cold FS Cold SS Cold Prep 32 F Safety precaution Don t open two front glass sections next to each other at the same time This can cause glass...

Page 12: ...re cooled products The unit will only maintain the product temperature Checking the product temperature During operation the display of the thermostat shows the temperature in the unit The maximum rea...

Page 13: ...relative humidity inside the cabinet WARNING Replace Tank after 1500 operating hours with mains water or after 5000 operating hours with demineralized water Sign Meaning Action Power Supply green LED...

Page 14: ...cy Inside Clean see section 5 2 Daily Outside Clean see section 5 3 Use Stainless Steel cleaning spray to remove stains and restoring the gloss Weekly Glass panes Clean front side and back glass panes...

Page 15: ...ing a damp cloth Clean the outside of the unit with a small amount of hot water and a mild cleanser and using a soft brush or sponge After cleaning it dry the outside with a cloth Treat all cleaned su...

Page 16: ...grid Air outlet grid Drain Ensure all parts are placed back in the correct position orientation Decks with slots at the customer side closed at the operator side Air intake guides A and B Front Glass...

Page 17: ...ng points yourself Is the power supply OK Check the fuses and the earth leakage switch in the meter cupboard Are all the switches in the correct position Item Malfunction Possible action Unit Unit doe...

Page 18: ...5 5 6 0 8 0 8 0 9 Climate Class NSF 7 Type I Refrigerant circuit volume remote R744 In3 81 112 143 174 205 236 267 298 330 361 391 422 453 Other on request Cold Self Service models Cold SS 30 40 50 60...

Page 19: ...igerant circuit volume remote R744 In3 81 112 143 174 205 236 267 298 330 361 391 422 453 Other on request FreshCold models FreshCold 30 40 50 60 70 80 90 100 110 120 130 140 150 Width inch 29 39 49 5...

Page 20: ...ght inch 33 7 8 Weight Net Approx lbs 397 529 661 794 926 1058 1190 1323 1455 1587 1720 1852 1984 Ambient temperature F 50 75 Relative Humidity 55 Noise level at workplace dB A 70 Voltage V 1 208 Freq...

Page 21: ...CC Cold US 21 24 Notes...

Page 22: ...CC Cold US 22 24 Notes...

Page 23: ...CC Cold US 23 24 Notes...

Page 24: ...CC Cold US 24 24 Fri Jado B V Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel 31 0 76 50 85 400 Fri Jado Inc 1401 Davey Road Suite 100 Woodridge IL 60517 USA Tel 1 630 633 7950 www frijado com...