Installation Manual Multi Deck 60/100/120 / Classic Deck form 9123789 rev. 06/2009
INSTALLATION OF THE MULTI DECK 60/100/120 & CLASSIC DECK HOT
Operate the Multi Deck 60/100/120 Hot and Classic Deck Hot at maximum temperature set-
ting to insure the proper working of the unit.
Operate the Multi Deck 60 Cold and the Classic Deck Cold merchandiser at minimum tempe-
rature setting to insure the proper working of the unit.
BEFORE FIRST USE
Each merchandiser is furnished on 4 casters of 80 mm. The Multi Deck 60 Hot & Cold and
Classic Deck Hot & Cold have 2 rigid casters on the back side and 2 locking swivel casters on
the customer side. The Multi Deck 100/120 Hot is furnished with 2 swivel casters on the back
side and 2 locking swivel casters on the customer side.
CASTERS
The minimum temperature of the environment should be 20°C for the Multi Deck 60/100/120
hot and Classic Deck hot. The maximum temperature of the environment should be 22°C and
the relative humidity should be maximum 65%.
Note:
Strong air-currents due to draughty doors, air-conditioninig outlets etc. will be detri-
mental to the proper operation.
Note:
The minimum temperature of the hot products that are loaded inside the Multi Deck
must be 85°C.
Note:
The maximum load per shelf is 20 kg. The load must be equally distributed over the
shelf.
GENERAL
INSTRUCTIONS FOR OPERATORS
After installation of the Multi Deck, the operator of the unit has to be instructed.
The instruction has to cover the following subjects:
• How to switch the unit on.
• Working of the unit.
• Run through the user manual.
• How to react for information or service calls.