9128135 Technical manual GGX7F  PLC V8    rev. 06/2020

Page 5

GREASE LOAD 02

OVEN ON: xx MINS

ST

OP

PARAMETER

MISCELLA

NEOUS

2x 

DATE      FRIDAY

29 MAY                   2020

         12:32 26

CALIBRAT. :+00S/WEE

VER

SION

CLO

CK

FAULT

DATE/HOUR SETUP

SUMMER TIME SETUP

1x 

ST

OP

PARAM

ETER

MISCELLANEOUS

1x 

MACRO xxx   FBD     xxx

NUM

constant value

xxxxx

MACRO 012   FBD     

058

CHOSE  FBD

?x 

MACRO 012   FBD     058

TIME   PROG   WEEKLY

n.00      00:00           ON

D:-- -- W -- -- -- -- W:12345

STOP

PARAMETER

MISCELLANEOUS

stop  program

      Press  OK

RUN

PARAMETER

MISCELLANEOUS

RUN program

RESET LATCHED 

            VALUES AND RUN

CANCEL

A

B

A

B

A

B

A

B

Pushing 

ESC

 

 and 

OK

 simultaneous, gives 3 options.

Selecting “Stop” and pushing 

OK

  will stop the program after 

confirming with 

OK

 .

Under “Parameter” the week flush can be set or disabled.

Under “Miscellaneous”, the clock can be set.

Week flush and Clock setting

Stop   

 

 

 

Parameter   

 

 

Miscellaneous

See previous page for method of changing.

 

ESC

 always helps to get out of the menu in case you get lost.

Backlight will switch off after 30 

seconds. Use a flashlight.

Choose FBD 058 !

Summary of Contents for 9128135

Page 1: ...et rid of the sediment of the cleaning agent from the Multisserie The level will drop for 5 cm One time each week the tank is flushed for 60 seconds The fluid level drops 10 cm Flushing happens at 22...

Page 2: ...during 10 seconds ex cept the flush drain valve After power on the PLC is waiting for the MTS cooking signal in the home screen When the MTS starts cooking the message grease load 01 and oven on appea...

Page 3: ...rced When the unit has no cleaning signal available the operators have to be instructed to force a skim cycle when they start the Multisserie cleaning program THE LID SWITCH AND PAUSE BUTTON THE MULTI...

Page 4: ...zones as shown default ON If no pork meat will be cooked it can be considered to switch OFF the middle zone KEY CODES AND PARAMETERS By pushing A each time opens successive parameter screens for 1 Ski...

Page 5: ...OP PARAMETER MISCELLANEOUS stop program Press OK RUN PARAMETER MISCELLANEOUS RUN program RESET LATCHED VALUES AND RUN CANCEL A B A B A B A B Pushing ESC and OK simultaneous gives 3 options Selecting S...

Page 6: ...Examples To empty the tank push ESC as soon it is empty at least before it starts refilling after 200 seconds To refill an empty the tank do not push ESC After 200 seconds the refilling starts Manual...

Page 7: ...ogram Press OK Save SAVE LOCK KEYPAD RESTORE 3x 2x restoring prog ram complete Press OK RUN RUN PROGRAM RESET WITH LATCHED VALUES AND RUN STOP GREASE LOAD password 3644 attemp1 1 1 Press OK 1x DEFAULT...

Page 8: ...Outputs 1 11 1 Inputs 8 L N 300W 10 A 1 2 3 5 6 2 S1 S2 W1 15v 115v PLC IN 1 2 3 4 4 T1 T1 W2 M1 M1 15v Ye Gy Br Bk Or Bl Rd 115v Cleaning signal Cooking signal 115V L N 10 A 10 A O2 O1 O3 O4 1 3 4 5...

Page 9: ...mpty the container as described above Start the Multisserie cleaning program Push the Green button 1 for more than 5 seconds this will start a skimming cycle After cleaning the Multisserie the next mo...

Page 10: ...is manual is not intended to be all encompas sing If you have not attended a training for this product you should read in its entirety the repair procedure you wish to performto determine if you have...

Reviews: