![Fresh-Aire FALLH-01 Series Quick Start Manual Download Page 4](http://html1.mh-extra.com/html/fresh-aire/fallh-01-series/fallh-01-series_quick-start-manual_2331800004.webp)
How to Change Wick
1.
Remove replacement wick from package and soak in water for 20 minutes.
2.
Remove the mist spout by turning it to the right until the icons align in the “unlock” position.
Lift up to remove the mist spout and set it aside.
3.
Unlock the spring loaded wick by turning the wick holder to the left and removing from the top
Cover.(Fig.4)
4.
Remove the old wick from the wick holder and discard.(Fig.7)
5.
Place the new, soaked wick into the wick holder.(Fig.7)
6.
Place the wick holder back on the unit and lock into place by turning the holder to the right.
NOTE : To order additional replacement wicks Model# FALLH-01, please visit
www.fresh-aire.com or call Futec Products Limited (852)2793 0886
Cleaning and Care
CAUTION:
Before cleaning the unit, turn power off and disconnect the
Plug from the unit.
Tank Cleaning
Remove the mist spout from the water tank. We suggest cleaning the
Water tank once every two to three weeks, depending on your water
Conditions. Clean tank using a 50/50 mix of vinegar and water.
Ultrasonic Membrane Cleaning
To clean the ultrasonic membrane, you must first remove the spring
loaded wick. Remove the mist spout.
Make a 50/50 solution of vinegar and water. Dip a soft bristle brush into
the solution and brush ultrasonic membrane. Wipe clean with a soft
cloth. Clean both sides of membrane.
NOTE
: DO NOT pour water into the ultrasonic membrane or submerge
in water.
Surface Cleaning
Clean the surface of the unit with a clean damp soft cloth.
Wick
Wick Holder
FIG.7
-- 5 --
-- 6 --