background image

 

19 

 

 

PROG— functional description: selects automatic program and FAT

 Operation 

instruction:

 

1.

 

This

 key may access to setting of automatic program when electronic meter is under 

full-manual operation mode 

2.

 

After under automatic program setting, fat rate test setting may be available if continue 
to use this key. 

3.

 

O

peration process: automatic program setting —fat rate test setting — Full-manual 

operation mode 

 

MODE

— functional description: selects countdown mode 

Operation instruction:  

1.

 

Th

is key may access to setting of countdown mode when electronic meter is under full-

manual operation mode 

2.

 

This key may be used to set next parameter under fat rate test setting mode 

3.

 

Operation processes in standby: Time countdown- Distance countdown- Calorie 
countdown- Full-manual operation mode 

4.

 

Operation processes under fat rate test setting: Set gender— Set age— Set height— Set 
weight— Fat rate test

 

 

SPEED

 +/- — functional description: Adjust speed when running and 

parameter values under parameter setting

 

Operation instruction:  

1.

 

M

ay adjust the running speed when electronic meter is on 

2.

 

May 

adjust parameter values set when under parameter setting

 

 

INCLINE

 +/- — functional description: Adjust incline when running and parameter 

values under parameter setting

 

Operation instruction:  

1.

 

May

 adjust incline when electronic meter is on 

2.

 

May

 adjust parameter values set under parameter setting

 

 

Speed 

shortcut

— functional description: Directly select speed when running 

and directly set a speed value on custom-defined program screen

 

Operation instruction:  

1.

 

May directly set corresponding speed when electronic meter is on

 

 

Incline 

shortcut

— functional description: Directly select incline when running 

and directly set a speed value under custom program setting

 

Operation instruction:  

1.

 

May directly set corresponding incline when electronic meter is on

 

 

PREV

/NEXT— functional description: Select songs in USB

 

Operation instruction:  

1. May switch songs in connection with USB (when MP3 jack is in vacancy) after power 

on and connect safety key

 

 

 

Summary of Contents for FF-FT500

Page 1: ...FF FT500 FRENCH FITNESS FT500 LIGHT COMMERCIAL TREADMILL ASSEMBLY MANUAL...

Page 2: ...Soft Running board LED 110 VAC 60Hz standard 2 0 HP continuous AC Motor Peak 4 0HP Speed range 0 62 15 5mph Incline Auto 0 10 Running Belt 580 x 1600mm FEATURES Max User Weight 330lb 150kg Weight 313l...

Page 3: ...4 5 3 6 4 8 5 9 6 11 7 13 8 15 9 17 10 24 11 27 12 28 13 31 CONTENTS...

Page 4: ...1 SAFETY INSTRUCTION...

Page 5: ...2 SPECIAL SAFETY INSTRUCTION...

Page 6: ...3 CONFIGURATION LIST...

Page 7: ......

Page 8: ...8 4 EXPLOSION DIAGRAM...

Page 9: ...9 y l One of each side 5 LIST OF EXPLOSION DIAGRAM...

Page 10: ...10 Lower cover of panel...

Page 11: ...11 6 STEPS OF ASSEMBLY...

Page 12: ...12...

Page 13: ...13 7 STRUCTURE OF FINISHED PRODUCT...

Page 14: ...14...

Page 15: ...15 8 OPERATING INSTRUCTION OF TREADMILL...

Page 16: ...16...

Page 17: ...RIE MODE 20 cals Shortest running time of P01 P12 automatic program 8 mins Longest running time of P1 P12 automatic program 99 mins Lowest incline displayed section 0 Highest incline displayed section...

Page 18: ...t display FATRATE TEST 6 When inputting gender display MALE 7 When inputting age display INPUT AGE 8 When inputting height display INPUT HEIGHT 9 When inputting weight display INPUT WEIGHT 10 When sta...

Page 19: ...escription Adjust speed when running and parameter values under parameter setting Operation instruction 1 May adjust the running speed when electronic meter is on 2 May adjust parameter values set whe...

Page 20: ...cline through INCLINE When the set time counts down to 0 the electronic meter gradually stops Once the speed reduces to 0 lattice window immediately displays End in company with 5 prompt tones each pe...

Page 21: ...fore such running When the program runs to the next section the speed and incline will be automatically adjusted to the corresponding defaults When the set time counts down to 0 the electronic meter g...

Page 22: ...treadmill is in an emergency stop Press QUICK STOP again to remove emergency stop Each time QUICK STOP is pressed the status circulates like Emergency stop Remove emergency stop Emergency stop Remove...

Page 23: ...e motor 3 Electronic meter display E08 Overvoltage protection 4 Electronic meter display E09 Overload protection 5 Electronic meter display E0A Phase loss Troubleshooting check if three phase connecti...

Page 24: ...24 10 DESCRIPTION OF PROGRAM...

Page 25: ...25 1 20 8KM H Ascension 0 10 18 Levels Mileage...

Page 26: ...26...

Page 27: ...27 11 11 FAULT ANALYSIS AND HANDLING...

Page 28: ...rear roller to tighten the running belt 2 Repeat step 1 to adjust the screw on the right Ensure that the regulating screw is turned by the same distance to make the rear roller parallel with the fram...

Page 29: ...29...

Page 30: ...30 13 IMPORTANT MATTER...

Page 31: ...31...

Reviews: