Fremco MicroFlow TOUCH Operating Manual Download Page 6

 

 

 

 
 

 

 

101-10051 OPERATING MANUAL ©2017-01-31 EN 
The material is copyright protected 

 

Fiber Protection Technology 

MicroFlow TOUCH has a unique protection 

technology securing that there is no damage to 

the fiber cable. The protection technology 

stops the machine if the fiber cable meets an 

obstacle. 

The stop occurs because the cable gets bent 

inside the fiber blowing machine as the fiber 
cable meets an obstacle. This is registered by a 

sensor, and the motor stops immediately.  

The machine will also stop automatically if the 

motor exceeds the preset maximum torque 

level (see section about Torque Off-Set for the 

minimum effect needed depending on the 

speed). 

In both cases of protection the machine stops 

immediately so the

 

fiber cable does not get 

damaged. 

 

 

 

Fault Sequence 

When the protection technology is activated, the machine starts the following fault sequence: 

 

The motor stops immediately. 

 

 

Short break. 

 

 

The machine pulls the fiber slightly backwards until the fiber is straight in the blowing junction 

block. 

 

 

The motor starts and accelerates to the preset maximum speed. 

 

 

If the protection technology is activated 3 times, the machine will come to a full stop, and an 

error message is shown in the display. 

 

 

Summary of Contents for MicroFlow TOUCH

Page 1: ...9900 Frederikshavn Denmark Tel 45 72 30 12 13 ORIGINAL OPERATING MANUAL MicroFlow TOUCH 101 10051 Operating Manual 2017 01 31 EN From Serial No 9328 1382 Fremco A S Ellehammervej 14 9900 Frederikshavn...

Page 2: ...ce 4 Identification 5 Application 5 Mounting and Preparations 5 Supply of Compressed Air and Electricity 5 Fiber Protection Technology 6 Fault Sequence 6 Display Symbols 7 Running the Fiber Blowing Ma...

Page 3: ...8 5 mm Microduct diameter 5 16 mm Blowing speed Up to 90 m min 295 ft min Recommended pressure and airflow 8 16 bar 120 230 psi 200 500 l min 7 1 17 7 cfm Power Supply 24V DC Can be connected to 100 2...

Page 4: ...to persons around the machine Never wear loose clothing WARNING Loose clothing may become entangled in the machine Use hearing protection if the air compressor is placed nearby The operator must make...

Page 5: ...ys store it in the carrying case Mounting and Preparations Make sure to place the machine on a stable foundation and to fasten it to withstand the forces which occur during use The adaptor plates in t...

Page 6: ...automatically if the motor exceeds the preset maximum torque level see section about Torque Off Set for the minimum effect needed depending on the speed In both cases of protection the machine stops i...

Page 7: ...info and return to main page Torque Motor torque Torque overload Info when machine is stopped by the torque overload system Meters Actual values for length speed and torque Fiber protection Info when...

Page 8: ...e used to stop the machine after a given distance set to 0 and the machine will continue indefinitely Press the ON OFF button and the machine will accelerate to the preset maximum speed After 10 20 me...

Page 9: ...the motor s maximum effect ADJUST Counter Here you can choose a distance that the cable should be blown When the pre set distance has been reached the machine will stop automatically If the counter i...

Page 10: ...is possible to Set and reset stop length by pressing to set length and to reset set to 0 disables the length stop function Increase decrease both speed and torque by pressing Access setup window See...

Page 11: ...n be increased decreased by pressing Press to go back to setup window Press to go back to main window Keypad For entering length stop Fiber Protection Warning Popup window when fiber protection monito...

Page 12: ...tor Torque Warning Popup window when a combination of fiber protection and motor torque occur during automatic restart cycle Press to confirm and go to main window Service Reminder Info window shows d...

Page 13: ...d m min Torque Off Set 10 5 20 5 30 10 40 10 50 15 60 15 70 20 80 20 90 25 Adaptor Plates It is important that the adaptor plates fit the actual size of the fiber cable and the microduct Below is an o...

Page 14: ...0051 MicroFlow TOUCH for microfiber cables 0 8 5 mm from Serial No 9328 1382 is manufactured in conformity with the EC Directives 2006 42 EC Technical file responsible Niels Soegaard Hansen Director R...

Reviews: