background image

Z9-PE-DEVKIT Quick Start Guide

Thank you for purchasing the FreeWave ZumLink™ Z9-PE-DEVKIT.

This

Quick Start Guide

provides procedures for the hardware connection and

configuration of the Z9-PE-DEVKIT.

For detailed information about the Z9-PE-DEVKIT, download the

ZumLink

Z9-PE User Manual

(FreeWave Part Number: LUM0076AA) from

http://support.freewave.com/

.

Warning!

The ZumLink Z9-PE-DEVKIT is sold as a fully enclosed

device, assembled at the FreeWave factory. Opening the ZumLink Z9-
PE-DEVKIT device voids the FreeWave warranty.

Included Equipment

This is the equipment included with the ZumLink device:

Qty

Description

2

Z9-PE-DEVKIT wireless device

Included with the Z9-PE-DEVKIT

2

½ Wave 900 MHz Stub Antenna, 2 dBi, SMA Male RF connector

(FreeWave Part Number: EAN0900SR)

2

Power Supply: 12VDC @ 800 mA

(FreeWave Part Number: EMD1280UW)

2

6.5 foot long shielded Ethernet cable

(FreeWave Part Number: ECD0658EB)

2

TNC Male to SMA Female Adapter

(FreeWave Part Number: ECN0313TS)

2

Power Adapter

(FreeWave Part Number: ASC0002ZL)

User-supplied Equipment

l

USB to micro-USB cable

Power Setup of the Z9-PE-DEVKIT

The Z9-PE-DEVKIT is approved to operate with an input voltage range of +6 to
+30VDC.

FREE

W

AVE Recommends

: All input power supply wires should be at least

20AWG

wires. A dedicated power supply line is preferred. The power supply

used MUST provide more current than the amount of current drain listed in
the specifications for the product and voltage. (at least mA at 12V)

Warning!

Use electrostatic discharge (ESD) protectors to protect the

radio from electric shock and provide filtered conditioned power with
over-voltage protection.

CLI Configuration

This procedure provides a Tera Term terminal connection to the ZumLink CLI.

The basic steps are:

A.

Connect the ZumLink to the Computer (on page 1)

B.

Tera Term Activation and ZumLink Setup (on page 2)

Note

: The images in this procedure are for Windows® 7 and/or Firefox®.

The dialog boxes and windows appear differently on each computer.

Connect the ZumLink to the Computer

1.

Connect the Z9-PE-DEVKIT to all four connections as shown in

Figure 1

.

The

AutoPlay

ZumLink,

AutoPlay FreeWave Drivers

, and ZumLink

windows open.

Figure 1: AutoPlay ZumLink window

Figure 2: AutoPlay FreeWave Drivers window

Figure 3: ZumLink window

Important!

: The ZumLink driver installs automatically.

Figure 4: Installing Driver message

Figure 5: Driver ready to use message

2.

Continue with

Tera Term Activation and ZumLink Setup (on page 2)

.

QSG0052AA Rev Oct-2017

Page 1 of 2

Copyright © 2017 FreeWave

Reviews: