Tera Term Activation and ZumLink Setup
Note
: The images in this procedure are for Windows® 7 and/or Firefox®.
The dialog boxes and windows appear differently on each computer.
1.
On the computer connected to the ZumLink device, open a terminal
program (e.g., Tera Term
).
2.
In Tera Term, on the
File
menu, select
New Connection
.
Figure 6: File menu > New Connection
The
Tera Term New Connection
dialog box opens.
3.
Click the
Port
list box arrow and select the COM port the ZumLink device is
connected to.
Figure 7: Select the Z9-PE-DEVKIT COM port
Important!
: The
Port
assignment varies from computer to computer.
4.
Click
OK
to save the changes and close the dialog box.
The Tera Term window shows the connected COM port and Baud rate in
the title bar of the window.
5.
In the Tera Term window, click the
Setup
menu and select
Serial Port
.
Figure 8: Serial menu > Setup Port
The
Tera Term: Serial Port Setup
dialog box opens with the default
ZumLink settings.
Figure 9: Tera Term: Serial Port Setup dialog box with default
settings
6.
Verify the COM port settings are:
Baud Rate
: 115200
Data
: 8 bit
Parity
: none
Stop
: 1 bit
7.
Click
OK
to save the changes and close the dialog box.
8.
In the Tera Term window, press <Enter>.
The ZumLink CLI Login returns.
9.
Type
admin
to login and press <Enter>.
10.
When prompted, type
admin
for the password and press <Enter>.
Note
: The password does not appear when typing - it looks blank.
The
FreeWave Shell
returns.
Figure 10: The FreeWave Shell returns.
11.
At the > prompt, type
ip_address=192.168.1.nnn
and press <Enter>.
12.
At the > prompt, type
nodeId=nnn
and press <Enter>.
Note
: Where
nnn
= the same unique 3 digit number.
13.
At the > prompt, type
save
and press <Enter>.
Note
: Go to
to login and download the latest
firmware for the Z9-PE-DEVKIT..
Registration is required to use this login.
Learn More
For additional product information about the Z9-PE-DEVKIT, visit
.
For additional assistance, contact a local reseller, or contact FreeWave Technologies, Inc. at 303.381.9200 or
1.866.923.6168, or by email at
.
FreeWave Technologies, Inc. reserves the right to make changes to this document or the product described
within it without notice. FreeWave assumes no responsibility or liability for the use of this document or the
infringement of any copyright or other proprietary right.
The ZumLink Z9-PE-DEVKIT complies with FCC Part 15 rules. Operation is subject to the following two
conditions: 1) This device may not cause harmful interference and 2) this device must accept any
interference received, including interference that may cause undesired operation.
FreeWave Technologies, Inc.
5395 Pearl Parkway, Suite 100
Boulder CO 80301
Local: 303.381.9200
Toll Free: 1.866.923.6168
Fax: 303.786.9948
QSG0052AA Rev Oct-2017
Page 2 of 2
Copyright © 2017 FreeWave