Double Tap
Settings
• Enable X DP
• Enable Y DP
• Enable Z DP
DP = Double Pulses
Enables detection of double pulses along the specified axis or axes.
For example, if you only want to see double taps on the X axis of the device,
then the Y and Z DP checkboxes should be cleared.
Ignore Latent
Pulses
Causes the device to ignore the Pulse Latency timer (set by the Pulse Latency Slider) and
detect taps directly after other taps.
Pulse Latency
slider
Sets the amount of time that
the device waits after a tap,
before registering the next
tap. Subsequent taps that
occur within this period are
ignored.
• Before using the Pulse or Second Pulse Latency slider,
click Reset Time Limits.
• After using the Pulse or Second Pulse Latency slider,
click Set Time Limits to change the setting.
Second Pulse
Latency slider
Sets the amount of time that
the device will wait to reset,
after receiving an initial
pulse.
A pulse detected after the
set time will be considered
a new first pulse.
Set Time Limits
Click Set to register the new settings with the device.
Reset Time Limits
Click Reset to enable a new configuration.
Single Tap
and Double
Tap
Detection
Indicator
(Read only)
Double Tap
The indicator turns green to indicate that a double tap has been detected.
• X Detected -
Direction X
• Y Detected -
Direction Y
• Z Detected -
Direction Z
The indicator(s) switch from red to green when a tap / double tap event is detected along
the specified axis or axes.
Event Detected
The indicator switches from red to green if a tap / double tap is detected.
Table 18. Full-System Evaluation – Pulse Detection screen (Continued)
Screen
frame
Field or option
Description