MMA865xFC Sensor Toolbox User’s Guide, Rev. 0
16
Freescale Semiconductor, Inc.
Operation
Mode
Sample Rate
Enables you to change the rate at which the device acquires data.
Note:
The tilt demo will not function at the 1.563 Hz Sample Rate.
Over-Sampling
Options for Data
Normal Mode
Normal operation.
Hi Res Mode
The device gives more accurate readings, but draws more
current.
Low Power Mode
The device draws less current than Normal mode does, but at
the expense of accuracy.
Low Noise Low Power
The device draws more current than Normal mode does, but less
current than Low Power mode does, and reduces noise.
Auto Calibrate
Directs the device to calculate the offsets for each axis (accounting for any error in
measurements). For maximum resolution, the calibration is done with a dynamic range of
8g and a sample rate of 1.563 Hz.
Note:
Before enabling Auto Calibrate mode, place the device on a flat and stationary
surface.
Note:
Before returning to active mode, it is necessary to set the Sample Rate back to a
usable value, because running Auto Calibrate sets the device to the 1.563 Hz
Sample Rate (a frequency at which the tilt application cannot function).
Dynamic
Range
• 2g
• 4g
• 8g
Sets the range over which the accelerometer is acquiring data.
Standby
Active
Standby
Sets the device to Standby mode.
Active
Sets the device to Active mode.
• Standby Mode
• Wake Mode
• Sleep Mode
Indicates the device’s status (Read only).
Note:
The device will never enter Sleep mode during this demo.
Table 2. Tilt Detection – Active/Standby screens (Continued)
Screen
frame
Field or option
Description