PDBx_MOD field descriptions
Field
Description
31–16
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
15–0
MOD
PDB Modulus
Specifies the period of the counter. When the counter reaches this value, it will be reset back to zero. If the
PDB is in Continuous mode, the count begins anew. Reading this field returns the value of the internal
register that is effective for the current cycle of PDB.
37.3.3 Counter register (PDBx_CNT)
Address: 4003_6000h base + 8h offset = 4003_6008h
Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
R
W
Reset
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
PDBx_CNT field descriptions
Field
Description
31–16
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
15–0
CNT
PDB Counter
Contains the current value of the counter.
37.3.4 Interrupt Delay register (PDBx_IDLY)
Address: 4003_6000h base + Ch offset = 4003_600Ch
Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
R
W
Reset
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
PDBx_IDLY field descriptions
Field
Description
31–16
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
15–0
IDLY
PDB Interrupt Delay
Specifies the delay value to schedule the PDB interrupt. It can be used to schedule an independent
interrupt at some point in the PDB cycle. If enabled, a PDB interrupt is generated, when the counter is
Table continues on the next page...
Memory map and register definition
K22F Sub-Family Reference Manual , Rev. 3, 7/2014
804
Freescale Semiconductor, Inc.