Installing the Software and Setting up the Hardware
5.3
Configuring the Hardware
Figure 8. KIT33882EKEVB plus FRDM-KL25Z Board Setup
5.3.1
Step-by-step Instructions for Setting up the Hardware using SPIGen
In order to perform the demonstration examples, first set up the evaluation board hardware and software as follows:
1.
Ready the computer, install the SPIGen software. Make sure the FRDM board has been flashed with the correct SPIGen
srec file.
2.
Connect the FRDM-KL25Z board to the KIT33882EKEVB evaluation board via the 20-pin ribbon cable. The
FRDM-KL25Z board must have a 20-pin male header soldered onto the top of the FRDM-KL25Z board in J2.
3.
Connect the mini USB cable between the FRDM-KL25Z board and the PC (use the KL25Z port, not the SDA port).
4.
Attach the DC power supply (without turning on the power) to the VPWR/GND terminal (J1).
5.
If desired, attach loads to the output terminals on the board (J3 through J10).
6.
Launch SPIGen and load the .spi configuration file from the kit's website and open it in SPIGen.
7.
Turn on the power supply and switch SW1 to the ON position.
8.
Send various commands via SPIGen using the predefined sequences available.
Notes:
Due to the limited number of available FSD I/O signals, several jumpers (J12 through J14) are available that control where DATA0,
DATA2, and CNTL0 are routed. They can be used for either IN0, IN2, and IN4 or IN4&IN5, IN2&IN3, and IN0&IN1, respectively.
Note: Pictured loads are examples only