21.
START5
- START5 device pin for fuel pump 1 (FP1) output control
22.
START6
- START6 device pin for fuel pump 2 (FP2) output control
23.
VSENSEP4
- VSENSEP4 device pin, voltage across R12 current sense resistor for the DC-DC converter
24.
VSENSEN4
- VSENSEN4 device pin, voltage across R12 current sense resistor for the DC-DC converter
25.
PGND
- power ground
26.
G_HS1
- G_HS1 device pin for HS1 driver control
27.
G_HS3
- G_HS3 device pin for HS3 driver control
28.
G_HS5
- G_HS5 device pin for HS5 driver control
29.
G_HS2
- G_HS2 device pin for HS2 driver control
30.
G_HS4
- G_HS4 device pin for HS4 driver control
31.
G_LS5
- G_LS5 device pin for LS5 driver control
32.
G_LS1
- G_LS1 device pin for LS1 driver control
33.
G_LS3
- G_LS3 device pin for LS3 driver control
34.
G_LS6
- G_LS6 device pin for LS6 driver control
35.
G_LS2
- G_LS2 device pin for LS2 driver control
36.
G_LS4
- G_LS4 device pin for LS4 driver control
37.
VSENSEP3
- VSENSEP3 device pin, voltage across R26 current sense resistor for the fuel pump bank
38.
VSENSEP1
- VSENSEP1 device pin, voltage across R21 current sense resistor for the injector bank 1
39.
VSENSEP2
- VSENSEP2 device pin, voltage across R22 current sense resistor for the injector bank 2
40.
VSENSEN3
- VSENSEN3 device pin, voltage across R26 current sense resistor for the fuel pump bank
41.
VSENSEN1
- VSENSEN1 device pin, voltage across R21 current sense resistor for the injector bank 1
42.
VSENSEN2
- VSENSEN2 device pin, voltage across R22 current sense resistor for the injector bank 2
43.
PGND
- power ground
44.
PGND
- power ground
45.
PGND
- power ground
46.
G_LS7
- G_LS7 device pin for LS7 driver control
11.3
Input Signal Definitions
The MC33816 EVB has nine logic level input signals used to control certain outputs or functions inside
the circuit. These 9 signals are:
1.
DRVEN
- Controls the state of the all the pre-driver outputs
2.
RESETB
- When the RESETB line is held low, the MC33816 is reset
3.
START1
- Provides start signal for Injector 1
4.
START2
- Provides start signal for Injector 2