background image

10

ADDITIONAL ADJUSTMENT

Top Weight Adjustment—

Tools required: Hammer, 1/8" punch, 3/16" roll pin

1. Lift the coupler cover from the top weight coupler.

2. Remove the roll pin from the top weight coupler

with an 1/8" punch and a hammer.

3. Align the hole in the cable coupler with the

appropriate adjustment hole in the top weight
coupler: 
• If more slack is needed in the cable, align the

cable coupler with a higher hole. 

• If less slack is needed in the cable, align the

cable coupler with a lower hole.

4. With the cable coupler aligned with the new hole,

drive a new roll pin into the top weight coupler
and cable coupler.

5. Lower the coupler cover over the top weight

coupler.

CABLE ADJUSTMENTS

CAUTION:

After making any cable adjustment, pull

the leg lever using a light load and have someone
make sure that the cable is not derailed from a pul-
ley or rubbing on a guard (see CABLE GUARDS on
page 9).

INITIAL ADJUSTMENT

Tower Pulley Adjustment–

Tools required: 5/16" hex key, 9/16" open end
wrench

1. Lift the top weight off the

weight stack and insert
the weight pin into the
third weight and the sixth
hole from the top of the
weight rod.

2. Loosen the locknut

attaching the pulley to the
bracket in the top of the
tower.

3. Move the pulley to the appropriate location in the

bracket: 
• If more slack is needed in the cable, move the

pulley downward. 

• If less slack is needed in the cable, move the

pulley upward.

4. Make sure that the pulley guard is properly ori-

ented (see CABLE GUARDS on page 9) and
retighten the locknut attaching the pulley to the
bracket.

5. Lift the top weight and remove the weight pin.

Lower the top weight onto the third weight.

6. Readjust as necessary.

Locknut

Set Screws

Cable

Top Weight

Coupler

Coupler Cover

Summary of Contents for Epic GZFI8043.3

Page 1: ...erial No Write the serial number in the space above for future reference Serial Number Decal inside tower QUESTIONS At FreeMotion Fitness we are committed to providing com plete customer satisfaction...

Page 2: ...MPORTANT PRECAUTIONS 3 WARNING DECAL PLACEMENT 4 BEFORE YOU BEGIN 5 ADJUSTMENTS 6 MAINTENANCE 7 CABLE DIAGRAM 12 PART LIST 13 EXPLODED DRAWING 14 HOW TO CONTACT CUSTOMER CARE Back Cover TABLE OF CONTE...

Page 3: ...acility staff imme diately 10 Keep hands and feet away from moving parts Do not lean on or rest your hands on the strength equipment when it is in use 11 Check all cables cable connections and pul ley...

Page 4: ...e indicated locations If a decal is missing or illegible see HOW TO CONTACT CUSTOMER CARE on the back cover of this manual and order a free replacement decal Apply the decal in the location shown Deca...

Page 5: ...r club And the advanced solutions to isolating individual muscle groups make the LEG PRESS strength equipment a key tool for members to reach their goals For your benefit read this manual carefully be...

Page 6: ...red handle on the bottom of the foot plate toward the seat To adjust the starting position of the foot plate back ward depress the yellow foot pedal push the foot plate to the desired position and the...

Page 7: ...oline or similar liquids WEEKLY 1 Hardware Check all nuts and bolts Tighten them as required Important All FREEMOTION EPIC cushions are fabricated using dense plywood with tee nuts installed for bolti...

Page 8: ...ng cross section C peeling skin D cracks or splits E strands hanging out or significant fraying 8 MONTHLY 1 Grips Check and replace as needed YEARLY OR AS REQUIRED 1 Weight Stack Guide Rods Clean and...

Page 9: ...leg lever is returned to the resting position If there is too much tension on the cable the top weight will not rest on the second weight and it may be difficult to insert the weight pin into the wei...

Page 10: ...ight load and have someone make sure that the cable is not derailed from a pul ley or rubbing on a guard see CABLE GUARDS on page 9 INITIAL ADJUSTMENT Tower Pulley Adjustment Tools required 5 16 hex k...

Page 11: ...ight tube 9 Reattach the cable to the top weight coupler 10 Clean and lubricate the guide rods by wiping them with a soft cloth containing a lightweight motor oil 10W 40 or 10W 30 weight Apply only a...

Page 12: ...cable guards have been assembled correctly If the belt or cable has not been correctly routed the strength equipment will not function prop erly and damage may occur The numbers show the correct rout...

Page 13: ...er 51 2 Weight Bumper 52 2 Wingnut 53 1 Spacer 54 2 3 8 x 3 4 Button Screw 55 1 8 Pivot Rod 56 6 1 Bearing 57 1 Cam Belt 58 6 1 Snap Ring 59 6 Nylon Washer 60 6 3 8 x 2 Bolt 61 4 Cable Guard 62 2 1 2...

Page 14: ...31 74 74 74 26 74 74 25 13 41 32 32 32 32 41 41 41 79 8 69 69 7 98 7 9 56 59 58 4 80 56 59 58 98 64 64 6 81 50 63 54 54 10 50 63 12 94 68 53 11 51 90 14 34 33 35 78 36 37 38 39 40 27 65 22 46 92 50 91...

Page 15: ...20 22 61 64 61 69 22 45 60 64 62 63 82 83 88 75 23 24 42 18 64 16 17 48 47 84 84 71 71 99 99 85 86 43 44 69 69 42 64 41 64 58 56 56 58 50 64 19 77 48 60 46 46 59 59 29 99 73 73 58 59 56 55 56 59 58 5...

Page 16: ...MODEL NUMBER of the product GZFI8043 3 The NAME of the product FREEMOTION EPIC LEG PRESS strength equipment The SERIAL NUMBER of the product see the front cover of this manual When ordering replaceme...

Reviews: