TROUBLE SHOOTING GUIDE
1. There is no display on screen after the machine is connected to the power source:
a: Please check the overload button, if the overload protector button bounce, please press
this button;
b: Please make sure the power source, overload protector ,the driver and the transformer
are connected well;
c: Please make sure the wire from the driver to the computer board are connected well.
d: Check the transformer, if it is wrong, please change a new one;
2. E01 display: Failure of signal from computer board to the driver
a: Please check the wire from the drive to the computer board, if the wire is broken, please
change a new one.
b: Please check the electronic parts in computer board, if it is wrong, change a new one;
c: Change a new transformer;
3. E02 display: Anti-explosion protects or motor problem
a: Please check the wire from motor, please connect the wire well; If this is no problem
with wire connection, please change a new motor.
b: Please is there bad smell from the control board, if the IGBT is shorted out, please
change a new driver;
c: Please make sure the voltage is in normal condition.
4. E03 display: No signal
a: If the E03 is displayed after start of 5 to 8 seconds, this is the failure of signal, please
check the connection of sensor is well. If it is not connected well, please connect again. If
the sensor do not work well, change a new sensor;
b: The signal in control board is wrong, please change a new driver;
5. E04 or E06 display: The failure of incline
a: Please check the signal wire of incline motor is connected well;
b: Please check the AC line of incline motor is connected to the right slot;
c: Please check the wire of incline motor, change a new wire or a new incline motor.
20