Control keys usage

 

 

Display and App

 

 

 

 

Power ON/OFF function 

 

The purifier has the following fan speed settings: 

Level 1 – Sleep 
Level 2 – Slow 

Level 3 – Medium 
Level 4 – High 

Automatic – based on the sensor feedback 

The appropriate fan speed can be selected 
according to the requirement. The four lights on 
the control panel correspond to the setting and the 
display panel also displays the setting. 

 

Or 
Timer 

The timer function can be used to set up the 
purifier running time. The device will automatically 
shut down once the settings are met. The display 
panel displays the timer settings. 1H, 4H, 8H, 12H, 
display time for the corresponding work time. 

 

Controls the device’s negative ion switch and UV 
functions. 

 

Function to control the humidification settings. 

 

Press and hold Wi-Fi button 5 seconds to enter the 
set-up mode. 

+

or 

Lock

 

To set up a child lock, press and hold the buttons 
for 3 seconds. The display panel shows the setting. 
Repeat the step to unlock the child lock. 

 

Sleep mode (night mode) – extra quiet operation 
and dimmed operating panel. This is only available 
on the remote control. 

 

The filter replacement key needs to be pressed 
after the filter is replaced. This is only available on 
the remote control. The symbol will be shown on 
the display when the filter needs to be changed. 

 

 

 

The display on the front of the device shows the following information: 

• PM2.5 value   

• Fan speed level 

• Temperature  

 • Humidity 

• Automatic mode 

• Wi-Fi 

 

The device can be controlled with the Tuya app, available in the Apple App 
Store and Google Play Store 

 

08 

 

09 

Summary of Contents for AIRPURIFIER10

Page 1: ...il info freedomforyou nl Phone 0031 297 282101 www freedomforyou nl The company reserves the rights to redesign this product and instruction without any advance notice Het bedijf behoudt zich het rech...

Page 2: ...asses Please read the Caution Warning section to ensure safe use Technical parameters Voltage Frequency 220V 50Hz Power 68W Anion volume 50 million pcs m3 CADR 550 m3 h Air volume 800 m3 h Applicable...

Page 3: ...not clog the air in and outlet for example do not place any obstacles in front of the in or outlet Place and use the device on a dry stable flat and horizontal plane Leave at least 20 cm of space on...

Page 4: ...Blue Excellent Purple Good Red Bad The air quality indicator turns on automatically when the device is turned on and takes a short time to detect indoor quality Built in air sensing measures air quali...

Page 5: ...en Remove the filter from the purifier Remove the packaging material from the filter Place the filter back into the purifier Put the bottom cover of the filter back and screw counter clockwise to tigh...

Page 6: ...tive ion switch and UV functions Function to control the humidification settings Press and hold Wi Fi button 5 seconds to enter the set up mode or Lock To set up a child lock press and hold the button...

Page 7: ...with abrasive corrosive or flammable cleaners such as bleach or alcohol Only pre filters can be cleaned with water Cleaning the purifier Clean the purifier inside and outside regularly to prevent dust...

Page 8: ...ion Make sure that the side with the pull piece faces you Turn off the purifier and unplug it Screw the bottom cover clockwise to open Remove the filter from the purifier Hold both sides of the discar...

Page 9: ...air more fully and simply The noise of purifier is too loud You have not removed all packaging materials from the filter Make sure you have removed all the packaging materials or The wind speed is to...

Page 10: ...deelte Veiligheidsmaatregelen om een veilig gebruik te garanderen Technische parameters Spanning Frequentie 220V 50Hz Stroom 68W Anionvolume 50 million pcs m3 CADR 550 m3 h Luchtvolume 800 m3 h Geschi...

Page 11: ...s toiletten of in de keuken Verstop de lucht in en uitlaat niet plaats bijvoorbeeld geen obstakels voor de in of uitlaat Plaats en gebruik het apparaat op een droog stabiel vlak en horizontaal vlak La...

Page 12: ...automatisch ingeschakeld wanneer het apparaat wordt ingeschakeld Als de luchtreiniger is ingeschakeld heeft de luchtkwaliteitssensor korte tijd nodig om de luchtkwaliteit binnenshuis te detecteren De...

Page 13: ...er uit de luchtreiniger Haal het filter uit de verpakking Plaats het filter terug in de luchtreiniger Plaats de bodemklep van het filter terug en schroef om vast te draaien Bemanning tegen de klok in...

Page 14: ...e ionenschakelaar en UV functies van het apparaat Functie om de bevochtigingsinstellingen te regelen Houd de Wi Fi knop 5 seconden ingedrukt om naar de instelmodus te gaan of Lock Om een kinderslot in...

Page 15: ...inigingsmiddelen zoals bleekmiddel of alcohol Alleen voorfilters kunnen met water worden gereinigd De luchtreiniger schoonmaken Reinig de luchtreiniger regelmatig van binnen en van buiten om stofophop...

Page 16: ...t de luchtreiniger uit en haal de stekker uit het stopcontact Schroef het onderste deksel met de klok mee om te openen Verwijder het filter uit de luchtreiniger Houd beide kanten van het weggegooide f...

Page 17: ...udiger kan zuiveren Het geluid van de luchtreiniger is te luid U hebt niet alle verpakkingsmaterialen van het filter verwijderd Zorg ervoor dat u al het verpakkingsmateriaal hebt verwijderd of De wind...

Reviews: