ACCESSORY INSTALLATION

Exhaust Duct Kit

The Exhaust Duct Kit is an accessory which, when used with the RCS-M1000 series air
conditioning units, will increase cooling efficiency by directing warm air exhaust out of the
room. The Exhaust Duct Kit can be used with other Freecom accessories, such as the
Window Panel Vent Kit, Sliding Door Vent Kit, Ceiling Vent Kit, or Through-the-Wall Kit for
maximum cooling efficiency.

WARNING: The Freecom Exhaust Duct Kit has been specially designed for use with

the RCS-M1000 series air conditioning units. Using other duct materials, compo-
nents, or extensions will decrease cooling efficiency or cause damage to the
product, and void your warranty.

CAUTION: DO NOT use Exhaust Duct Kit when operating the unit as a dehumidifier.

1.

Press “POWER ON/OFF” button to stop unit if it is
operating. Unplug power cord from outlet.

2.

Locate foam gaskets and attachment clips on end of large
connector flange. Arrange connector flange so wider attachment
clip will be to the left when connected to the exhaust vent on the
back of the unit.

3.

Hold connector flange at an angle to the exhaust vent. Press
foam gasket on left side of flange against left edge of exhaust
vent opening. Slide connector to the left while allowing larger
clip to fit behind left side of vent opening. Push left clip as far
as it will go against the side of vent opening.

4.

Push right side of connector flange into right side of vent
opening. Adjust connector flange slightly so it is square in the
opening. The foam gaskets will rest between the connector
and the edge of the vent opening.

5.

Push nozzle onto small connector end of vent duct pipe.

6.

Place nozzle out an open window or through an exterior wall.
Contact an experienced contractor or qualified craftsman to
modify wall or windows, if necessary.

To use the Exhaust Duct Kit with other Freecom accessories, follow installation instruc-
tions supplied with the accessory.

11

Summary of Contents for RCS-M1000T

Page 1: ......

Page 2: ...it in its upright position for a minimum of two hours before operating For best results and more enjoyment from your new FREECOM portable air conditioning unit please read this instruction manual care...

Page 3: ...ndow Panel Vent Kit two sizes available special order only prevents outside air from entering the room when used with the Exhaust Ducting Kit Sliding Door Vent Kit special order only allows exhaust ai...

Page 4: ...95 F 35 C 8 Compressor delay feature may be active Unplug unit and wait for 3 5 minutes Plug unit into out let and press POWER ON OFF switch 1 Check and clean air filters 2 Check louvers and grills fo...

Page 5: ...nk are completely dry before installation operation 1 Press POWER ON OFF button to stop unit if it is operating Unplug power cord from outlet 2 Wipe cabinet exterior with a soft cloth dampened with wa...

Page 6: ...highly efficient compressor It has been designed to operate in a vertical position only Should it be necessary to lay the unit on its side place it in its upright position for a minimum of two hours b...

Page 7: ...de l exposition directe du soleil en fermant rideaux et stores etc pour am liorer le rafra chissement Ne pas placer l appareil pr s de rideaux qui risquent de bloquer l entr e ou la sortie d air dista...

Page 8: ...ch filter Turn each filter over and vacuum other side Use care not to damage or puncture the filter mesh DO NOT use brushes brooms or other course materials to clean the filters 4 Hold each air filter...

Page 9: ...ank straight out of unit 3 Carefully carry the tank to a sink or tub and empty its contents Use water and a mild detergent to rinse and clean the inside and outside of the tank Dry tank completely and...

Page 10: ...NOT expose unit to water or moisture DO NOT use outdoors CAUTION Failure to follow the safety information below can result in minor personal injury property damage damage to the unit and voiding your...

Page 11: ...Control Panel B Horizontal Air Louver up and down C Air Outlet D Vertical Air Louver left to right E Built in Handle F Air Filters G Condensate Water Tank H Power Cord I Plug J Caster Wheels K Power C...

Page 12: ...oam gaskets and attachment clips on end of large connector flange Arrange connector flange so wider attachment clip will be to the left when connected to the exhaust vent on the back of the unit 3 Hol...

Page 13: ...d the metal prongs and always push plug into outlet by using the molded plug Never use the electrical plug to start or stop the unit and avoid pulling folding or stretching the electrical cord 2 Press...

Page 14: ...THM DEHUMID 3 TIMER Adjustable 3 hour timer can be programmed to turn off air conditioner after 1 2 or 3 hours 4 AUTO LOUVER Choose between fixed position or oscillating 70 degrees vertical louvers 5...

Page 15: ...or other obstructions Carefully push the unit on its caster wheels to desired location CAUTION Do not operate unit without condensate water tank and air filters properly in place 3 Check that condensa...

Page 16: ...air will begin blowing from the front louvers NOTE This unit is equipped with a special safety time delay feature The compressor cooling mechanism may be delayed for up to five minutes This safety fea...

Reviews: