FPQ41 Superminor Issue 1
11
Four clips hold the filter hood (3) in place
(marked * on the diagram). Work on one clip
at a time.
Pull up the lower part of the clip
(1)
to
release the top part of the clip that secures
the filter hood to the Superminor turret.
Pull down the top of the clip
(2)
.
Repeat this for each clip until the filter hood
can be removed.
Remove the filter hood from the
Superminor.
Figure 4-3: Remove the filter hood
2.
Remove the filter:
Note
A 200 micron filter is fitted to the
Superminor when it is first supplied.
Carefully remove the used filter from the
Superminor and dispose of the waste
products in accordance with your company
procedures.
Note
Nylon filters (sizes 100 to 1000 micron)
can be cleaned and rinsed and then
reused. See section 6.2.1.
Figure 4-4: Remove the filter
Do not re-use disposable filters
(needle-felt filters with mesh sizes of
5 to 75 micron).
3.
Fit the filter:
Select the correct grade of filter for the
cleaning operation you will be carrying out.
Place the filter into the filter basket in the
Superminor turret.
Make sure that the body of the filter is
smoothed out into the Superminor and that
the rim of the filter fits into the recess in the
edge of the Superminor turret next to the
seal
(1)
.
Figure 4-5: Fit the filter
The rim of the filter should be level
with the seal in the filter basket in
the Superminor turret.