3

Refer to the included Inline System’s performance tables 
(Appendix 1) and friction loss tables (Appendix 2) to 
determine the amount of head lost for a given application. 
PRESSURE TANK

NOTE: 1 PSI = 0.068 bar
The Inline System needs a small pressure tank placed on 
the pump outlet to maintain constant pressure. The tank 
supplies water while the pump ramps up to speed and 
in circumstances where only a small amount of water is 
required for a short period of time. In addition, the tank 
prevents water hammer by acting as a system buffer. This 
buffer also helps to prevent pressure spikes when there is 
a sudden change in demand.
For 12 gpm (45 LPM) flow or greater, minimum pressure 
tank size is 4 gallons (15 L); for 12 gpm (45 LPM) flow, 
minimum pressure tank size is 2 gallons (7.5 L).
Pressure Tank Pre-charge (PSI)
The pressure tank pre-charge setting should be 70% of 
the system pressure sensor setting as indicated in the 
preceeding table.
NOTE: Check tank pre-charge regularly to maintain 
optimum pressure regulation.

INSTALLATION

NOTICE: READ AND FOLLOW ALL INSTRUCTIONS.

WARNING

 Hazardous voltage can shock, burn or 

cause death.

CAUTION

 Improper wiring can result in permanent 

damage to the system. Pump connection must comply 
with National Electric Code (NEC) or Canadian Electric 
Code (CEC), and all applicable local codes.

CAUTION

 If you are not sure of the proper electrical 

connections, employ a competent electrician for the 
installation. This ensures the installation complies with all 
noted electrical codes.

 Disconnect power at electrical panel before making 

any electrical connections. Supply voltage must be  
+/- 10% of Inline System nameplate voltage (230V).
Low or high voltage can damage the Inline System and 
will void the warranty. Connect pump to dedicated branch 
circuit with no other appliances on it. 

System Pressure  

(at Pressure Sensor)  

Pressure Tank 

Setting (±2 PSI)

25

 18

30

 21

35

 25

40

 28

45 

 32

50 Factory Setting

35

55 

 39

60

 42

65

 46

70

 49

75

 53

80

 56

 Do not operate pump unless pump is grounded.
 A fused disconnect switch or circuit breaker should  

be placed at or near the pump as required by local 
electrical codes.
INSTALLATION PROCEDURE PLUMBING
1. Disconnect electrical power at the main breaker.
2. Drain the system (if applicable).
3. Mount the Inline System in the desired location  
using mounting screws. Screw locations are shown in 
FIGURE 1. The Inline System may be installed in  
any orientation.  
4. Install inlet and outlet plumbing and pressure tank as 
shown in 

FIGURE 2.  A check valve must be installed 

in the inlet and outlet plumbing. The outlet check valve 
should be between the pump and the pressure tank to 
prevent the possibility of backflow in to public water 
systems, and to ensure proper system operation. The 
inlet check valve should be used when no other backflow 
prevention device is present. This inlet check valve 
should be installed before the optional bypass loop if that 
plumbing is used. Be sure to check all local plumbing 
codes to ensure that all requirements pertaining to 
backflow prevention are met.   
5. Install the pressure sensors at the pressure tank tee 
downstream of the pressure tank. (The pressure tank 
should be between the pressure sensor and the pump.) 
The pressure sensor has a 1/4-18 National Pipe Thread 
(NPT) connection. The pressure sensor should not be 
installed in an inverted orientation (upside down). Make 
sure the pressure sensor and tank are not located more 
than 5 feet off the main piping.
6. Install a pressure relief valve downstream of the check 
valve. The discharge must be plumbed to a drain rated for 
maximum pump output at relief pressure setting.

WARNING

 Inline systems can develop very high 

pressure in some situations. Always install a pressure 
relief valve able to pass full pump flow at 100 PSI  
(6.9 bar). Install the pressure relief valve near the  
pressure tank.

WARNING

Serious or fatal electric shock may result from failure to 
connect the Inline System to the service entrance ground.  
Also ground metal plumbing and all other metal near the 
Inline System.  When grounding these components, use a 
wire no smaller than the power supply wires from the circuit 
breaker to the Inline System.  To reduce the risk of electric 
shock, disconnect power before working on or around the 
water system.
CAPACITORS INSIDE THE INLINE SYSTEM CONTROLLER 
CAN STILL HOLD LETHAL VOLTAGE EVEN AFTER POWER 
HAS BEEN DISCONNECTED. ALLOW 5 MINUTES FOR 
DANGEROUS INTERNAL VOLTAGE TO DISCHARGE 
BEFORE REMOVING ACCESS PANEL.
This pump has not been investigated for use in swimming 
pool or marine areas. 

Summary of Contents for SubDrive Inline 1100

Page 1: ...dous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNING Hazardous voltage Can shock burn or cause death Ground pump before connecting to power supply Disconnect power before working on pump motor or tank WARNI NG TERMINAL USING WIRE NO SMALLER THAN MOTOR CABLE WIRES TO REDUCE RISK OF ELECTRICAL SHOCK DIS...

Page 2: ...60 PSI 4 1 bar Stainless steel construction for all wetted surfaces Drive Controller Protection Features No in rush power on transient current Over pressure shut off optional See Replacement Parts Section Low water shut off Locked pump detection shut off High voltage lightning surge protection Low line voltage protection Motor under and overload protection Open and short circuit protection NEMA 4 ...

Page 3: ...roller will try to restart when the fault condition subsides INSTALLATION LOCATION OF THE Inline Constant Pressure System Decide on a location for the pump installation that is suitable based on the enclosure rating of the Inline System WARNING Liquid tight conduit and fittings must be used to maintain NEMA 4 rating Choose a clean well ventilated location that provides protection from freezing flo...

Page 4: ... electrical power at the main breaker 2 Drain the system if applicable 3 Mount the Inline System in the desired location using mounting screws Screw locations are shown in FIGURE 1 The Inline System may be installed in any orientation 4 Install inlet and outlet plumbing and pressure tank as shown in FIGURE 2 A check valve must be installed in the inlet and outlet plumbing The outlet check valve sh...

Page 5: ...y look like Ball Valve Check Valve Ball Valve Union Coupling Union Coupling To Home Water Supply Inline System Pressure Shut off Sensor optional 2 Gallon Tank Check Valve Power Ball Valve Pressure Sensor Discharge into drain rated for max pump output at relief pressure Pressure Relief Valve Pressure Gauge Flow Optional Bypass 5 feet or Less Check Valve Figure 2 NOTICE If system plumbing does not h...

Page 6: ...PERATION RATINGS CAUTION Maximum operating pressure should be limited to whatever level is needed to protect the rest of the existing system plumbing When required a pressure relief valve should be installed and or the optional over pressure sensor can be used Maximum suction pressure is 70 psi 4 8 bar Maximum water temperature is 104 F 40 C Avoid pumping abrasive or sandy water WARNING Hazardous ...

Page 7: ...s the steady flow feature reduces the controller s reaction time to sudden changes in flow If it is necessary to adjust the pressure control remove power and allow the controller to discharge Wait 5 minutes to allow internal voltage to dissipate locate the DIP switch bank Use a small screwdriver provided to move position 2 to ON as shown restrictions in the plumbing and will be more pronounced the...

Page 8: ...to pump before servicing unit DRAINING NOTICE Disconnecting the pump will not necessarily drain all other parts of the piping system If there are any concerns with the proper procedure or necessity of draining the suction plumbing contact a water systems professional All piping and water tanks exposed to freezing weather should be drained If there are any concerns with the proper procedure to drai...

Page 9: ...8 Overpressure Switch H 305707909 19 2 Gallon Pump Tank Kit I 305707910 1 Item ships with fastener kit D REPLACEMENT PARTS CONTINUED Spare Parts Kits for Inline 1100 LG Number Description Kit Grouping Identifier Repair Part Order Codes 1 Drive Assembly A 305707907 2 Mounting Posts 3 Pump Motor Assembly B 305707902 4 Mounting Feet C 305707903 5 10 24x1 625 Pan Head Torx D 305707904 6 10 Lock Washer...

Page 10: ... N A 5 OPEN MOTOR CIRCUIT Loose motor connection Wires to motor are open circuit Check motor connection 6 SHORT CIRCUIT When fault is indicated immediately after power up Short circuit due to defective cable motor or drive Check motor connections Replace drive or motor 7 OVERHEATED DRIVE High ambient temperature Improper ventilation Clogged heat sink Ambient temperature has exceeded 104 F 40 C Shi...

Page 11: ...Curves 5 10 15 20 25 30 35 40 45 50 0 10 20 30 40 50 60 70 80 Feet M 3 PH GPM LPM Meters PSI Recommended Continuous Operating Range 0 10 20 30 40 50 0 20 40 60 80 100 120 140 160 180 0 1 2 3 4 5 6 7 8 9 10 11 0 20 40 60 80 100 120 140 160 180 ...

Page 12: ... 15 8 103 56 6 18 0 87 7 1 1 4 Schedule 40 pipe 1 380 in i d Type L Copper tube 1 265 in i d GPM Velocity Ft S Friction Loss Ft Hd 100 of pipe Velocity Ft S Ft Hd 100 Pipe Fric Loss C 130 Steel C 100 PVC C 140 4 0 0 86 0 56 0 30 1 02 0 52 6 0 1 29 1 20 0 65 1 53 1 12 8 0 1 72 2 04 1 10 2 04 1 92 10 2 15 3 08 1 67 2 55 2 90 12 2 57 4 31 2 33 3 06 4 04 14 2 00 5 73 3 10 3 57 5 35 16 3 43 7 34 3 96 4...

Page 13: ...or 4 Product was damaged as a result of negligence abuse accident misapplication tampering alteration improper installation operation maintenance or storage nor to an excess of recommended maximums as set forth in the product instructions NEITHER SELLER NOR THE COMPANY SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT INCIDENTAL OR CONSEQUENTIAL INCLUDING BUT NOT LIMITED TO INCIDENTAL OR CONSEQ...

Reviews: