background image

TESTING

 1.  Turn on power.
 2.  Remove motor/tank cover assembly and hold level.
 3.  Test motor switch by raising motor switch float with finger (Figure 6). Motor 

should turn on just before float contacts cover. 

 4.  Test safety switch by raising safety switch float with finger. Safety switch 

should activate before float contacts cover.

 5.  Replace motor/tank cover assembly on tank.
This pump is suitable for gas furnace condensate applications. Caution must 

be taken to ensure acidity of condensate does not increase below the average 

pH of 3.4 (to prevent localized pocket of acid that acts like a battery causing 

pitting) by routinely cleaning or flushing tank with fresh water.

INTRODUCTION

FR

Votre pompe a condensats Little Giant est concue comme une unite automa-

tique d’evacuation des condensats. Elle evacue l’eau condensee egouttant de 

la volute de l’evaporateur d’un systeme de climatisation. La pomp est actionee 

par un mechisme flotteur/ interrupteur lequel entraine le demarrage dela 

pompe oorsque environ 2 po 1/4 d’eau s’accumule dans le reservoir. La pompe 

s’arrete automatiquement lorsqu’il ne reste plus qu’environ 1 po 1/4 d’eau.
Votre nouvelle pompe Little Giant a été fabriquée avec les meilleurs matériaux et 

avec le plus grand soin. Elle a été conçue pour foncionner bien et longtemps.
Les pompes Little Giant sont soigneusement emballées, et testées pour assurer 

une livraison et un fonctionnement sans problèmes. Lorsque vous recevez 

votre pompe, examinez-la attentivement pour vous assurer qu il n y a pas eu de 

pièce cassée ou endommagée pendant l acheminement. S il y a eu des dégats, 

prenez-en note et signalez-le au magasin où vous avez acheté la pompe. Ils 

vous aideront pour le remplacement ou la réparation, si nécessaire. Cette pompe 

est conçue pour pomper de l eau. NE POMPEZ PAS de produit chimique, de 

solvant, d eau salée, ou de liquides épais tels que des huiles ou de la graisse.
BIEN LIRE LES INSTRUCTIONS AVANT D’INSTALLER, DE FAIRE 

FONCTIONNER OU D’ENTRETENIR LA POMPE LITTLE GIANT. IL FAUT 

CONNAÎTRE L’APPLICATION, LES LIMITESET LES DANGERS POTENTIELS 

DE LA POMPE. PROTÉGEZ-VOUS ET LES AUTRES EN RESPECTANT TOUTES 

LES NORMES DE SÉCURITÉ. LE NON-RESPECT DES INSTRUCTIONS PEUT 

CAUSER DES ATTEINTES AUX PERSONNES OU À LA PROPRIÉTÉ! GARDER 

LE PRÉSENT DOCUMENT POUR RÉFÉRENCE ULTÉRIEURE.
L´INSTALLATION ET LES BRANCHEMENTS DOIVENT ÊTRE EFFECTUÉS 

PAR DES PROFESSIONNELS.

DIRECTIVES DE SECURITE

NE PAS UTILISER POUR POMPER DES LIQUIDES EXPLOSIFS OU 

INFLAMMABLES (ESSENCE, HUILE, KÉROSÈNE, ETC.) NE PAS UTILISER 

DANS UN ENVIRONNEMENT PROPICE AUX EXPLOSIONS. UTILISER AVEC 

DES LIQUIDES COMPATIBLES AVEC LES MATÉRIAUX DE LA POMPE.
NE PAS MANIPULER LA PUMPE LES MAINS HUMIDES, LES PIEDS POSES 

SURE UNE SURFACE MOUILLEE OU HUMIDE, OU LES PIEDS DANS L’EAU.
VOTRE POMPE VIENT AVEC UN FIL DE MISE A LA TERRE ET/OU UNE 

PRISE A TROIS BRANCHES. AFIN DE RÉDUIRE LE RUSQUE DE CHOC 

ÉLECTRIQUE, S’ASSURER QUE LA POMPE EST BRANCHÉE A UNE PRISE 

CORRECTEMENT MISE A LA TERRE.
L’UTILISATION D’UN OU DE PLUSIEURS SYSTÈMES AUXILIAIRES ET/OU D’UN 

SYSTÈME D’ALARME EST RECOMMANDÉE POUR TOUTE INSTALLATION 

POTENTIELLEMENT DANGEREUSE (FUITE OU DÉFECTUOSITÉ CAUSÉES 

PAR UNE COUPURE DE COURANT, UN BLOCAGE DU CIRCUIT DE 

REFOULEMENT OU POUR TOUTE AUTRE RAISON) POUR LES PERSONNES 

OU LA PROPRIËTË.
IMMOBILISER LA POMPE ET LES TUYAUX LORS DE L’INSTALLATION ET DE 

L’UTILISATION AFIN D’ËVITER TOUT RISQUE DE DOMMAGES AUX TUYAUX. 

À LA POMPE AUX ROULEMENTS À BILLE DU MOTEUR, ETC.

INSTALLATION

 1.  Avant d’installer la pompe, laisser le climatiseur effectuer quelques cycles 

pour collecter le condensat dans un contenant séparé afin de faciliter 

l’évacuation des huiles résiduelles qui pourraient rester dans le système.

 2.  Déballer la pompe avec précaution en faisant gliser l’emballage. Enlever 

l’emballage de carton des fetes d’aération qui se trouvent sur le courvercle 

du moteur. Cet emballage est destiné à éviter le mouvement des commu-

tateurs pendant le transport (Figure 1).

  3.  Montage-Deux fentes situées à l’extrémité du couvercle de réservoir, permettent 

le montage. Celui-ci doit être fait prés d’un climatiseur ou d’un mur (Figure 

Figure 3

Figure 4

Figure 5

Figure 6

2

Reviews: